Permit: TC-RES-0624-03623

Parcel: 137116270


Addresses:

1527 W BREAKWELL ST

Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
01/22/2026 COT - RSME - Mechanical Final  Re-inspection required 1-22-26: no power to receptacle east wall of living room,at east wall & south wall of family room, missing restroom fan cover, missing valve at restroom lavatory, missing anti-tip device at stove, missing hammer arrestors for dishwasher, insulate hot water line of water heater with R3 insulation, missing electrical receptacle behind refrigerator, missing receptacle covers at garage, behind refrigerator, remove cover smoke detector in bedroom, lower hallway thermostat to 48" o.c., missing a/c condensation line to lavatories-see detail M2.0 detail's 5 & 8, arch fault breakers are required for habitable areas-living room, kitchen, family room, hallways and bedrooms, missing 4 breakers at main panel-see schedule. STOPPED INSPECTION -ADDITIONAL ITEMS MAY BE ADDED.
02/05/2026 COT - RSME - Mechanical Final  Not Ready Provide KO seal underneath at main panel. Provide shielded exterior lighting fixtures. Provide WR receptacle at all outdoor locations. Secure overflow pan at air handler. Provide proper caps for clean outs in wall. Provide anti tip for range. Lower t stat to 48”. Provide gfci receptacle at washer. Provide a 20 min rated door and has to be self closing and self latching. Ensure receptacles in garage are gfci protected. Insulate hot water line at water heater. R3 insulation. Provide traffic rated cover at exterior clean out. Secure seal right from ground. Insulate main water line. Provide insulation and shield cover at line sets. Ensure weather rated cover at yolk at service outlet. Remove old solar wiring to the panel. 2/5/2026
02/09/2026 COT - RSME - Mechanical Final  Passed All corrections are made. 2/9/2026