Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
2227 E HELEN ST
Address NEW:
2227 E HELEN ST
Apply Date:
06/04/2023
Applicant:
Stephen Anson
Description:
SFR with Attached ADU

Permit Reviews

Permit Number - TC-RES-0623-05642
Permit Status: Complete
Permit Description: SFR with Attached ADU
Start Date Submittal Complete Date Status  
06/05/2023 RESIDENTIAL NEW DWELLING v.1 06/15/2023 REQUIRES RESUBMIT Review Details
06/23/2023 RESIDENTIAL NEW DWELLING v.2 07/10/2023 REQUIRES RESUBMIT Review Details
07/24/2023 RESIDENTIAL NEW DWELLING v.4 07/24/2023 APPROVED Review Details
07/11/2023 RESIDENTIAL NEW DWELLING v.3 07/17/2023 REQUIRES RESUBMIT Review Details
07/24/2023 RESTAMP - RESIDENTIAL v.1 07/25/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-0623-05642
Permit Status: Complete
Permit Description: SFR with Attached ADU
Date Description Comments
07/13/2023 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
07/13/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0623-05642
Permite Description: SFR with Attached ADU
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
06/13/2024 COT - BULD - SWG Clearance N/A Not Applicable
06/13/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable
07/22/2024 COT - RSME - Mechanical Final N/A Partial Pass
07/22/2024 RSBU - Building Final N/A Not Ready
07/22/2024 COT - RSPL - Plumbing Final N/A Partial Pass
07/22/2024 COT - RSEL - Electrical Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0623-05642
Permit Description: SFR with Attached ADU
Total Completed Inspections - 16
Date Description Inspector Results Comments
09/15/2023 COT - RSPL - Rough Soil Passed Okay to backfill. Shading required. 9/15/2023
09/25/2023 COT - RSBU - Excavation/Rebar/Zoning Passed Footing are properly dug to 12" below grade, with rebar reinforcement in place. Ufer ground is in place and properly connected to rebar reinforcement at bottom of footer.
09/25/2023 COT - RSBU - Preslab Passed Footing are properly dug to 12" below grade, with rebar reinforcement in place. Ufer ground is in place and properly connected to rebar reinforcement at bottom of footer. Okay to pour concrete slab.
09/25/2023 COT - RSEL - Grounding/Bonding Passed Footing are properly dug to 12" below grade, with rebar reinforcement in place. Ufer ground is in place and properly connected to rebar reinforcement at bottom of footer.
10/16/2023 COT - RSPL - Sewer Passed
10/20/2023 BULD - Electrical Clearance Passed 10/20/23: ECO TEP CLEARANCE 2227 E Helen St Unit #1 and Unit #2
10/30/2023 COT - RSBU - Masonry Pregrout Passed
11/02/2023 COT - RSPL - Yard Water Line Passed 11/2/23: Ok to back-fill
12/14/2023 COT - RSBU - Roof Nailing Passed
02/23/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Mechanical, electrical, and plumbing rough-in is complete on main residence and attached ADU. Okay to install drywall, tape, and texture.
02/23/2024 COT - RSBU - Firewall/Fire Barrier/Firestop Passed Firewall between main house and ADU is ICCF concrete block from floor to top of roof deck on main house. Okay to drywall firewalls and interior walls and ceiling.
07/22/2024 COT - RSEL - Outdoor Lighting Passed
02/03/2025 COT - RSME - Mechanical Final Passed
02/03/2025 RSBU - Building Final Passed Ok to make application for Certificate of Occupancy.
02/03/2025 COT - RSPL - Plumbing Final Passed
02/03/2025 COT - RSEL - Electrical Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-RESUBMITTAL 2227 E HELEN ST 2.0_V5.PDF DOCUMENTS VIEW
2227 E HELEN ST CONSTRUCTION NOTES_V1.PDF DOCUMENTS VIEW
2301456_GEOTECHNICAL REPORT COMPILED_V1.PDF DOCUMENTS VIEW
EQUIPMENT CUTSHEETS_V1.PDF DOCUMENTS VIEW
MANUAL J FOR BOTH DWELLINGS_V1.PDF DOCUMENTS VIEW
OUTDOOR LIGHTING_V1.PDF DOCUMENTS VIEW
PDSD_OWNER_BUILDER_AFFIDAVIT_V1.PDF DOCUMENTS VIEW
RESCHECK CERTIFICATE_V1.PDF DOCUMENTS VIEW
RESIDENTIAL_SUBMITTAL_REQUIREMENTS_V1.PDF DOCUMENTS VIEW