Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - TC-RES-0623-05642
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/17/2023 | Site Zoning | APPROVED | |||
| 07/17/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/13/2023 | Residential Building | REQUIRES RESUBMIT | TC-RES-0623-05642 R1 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter back check time, please provide an updated complete plan set with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet Zoning and other departmental requirements, conditions and concerns before permit approval. GENERAL COMMENTS: 1. Show the square footage of covered carport or patio areas. FLOOR PLANS: 1. Provide a landing or floor (slab) surface at all exterior doors. A landing must be at least as wide as the door it serves and 36” in the direction of travel, R311.3. STRUCTURAL PLANS: 1. Provide an engineer’s calculation, design and seal for a performance design when minimum sizes are not code compliant with the IRC, R301.1 Include the cantilever beam showing appropriate uplift fastening, and rafters extending (overhang) beyond 24”, R802.7.1.1. 2. Provide a header schedule for supporting roofs over openings consistent with Table 502.5(1) & R602.7(1). PLUMBING PLANS: 1. Show a plumbing code recognized by the City of Tucson, 2018 IRC. Update note #1 on sheet #8. 2. Tucson Water Department limits flow rates for each water meter size in compliance with P2903.7. Show an appropriate “yard pipe” size of a minimum 1”. Update note #2. MECHANICAL PLANS: 1. Show a mechanical code recognized by the City of Tucson, 2018 IRC. Update note #2 on sheet #7. ELECTRICAL PLANS: 1. Show an electrical code recognized by the City of Tucson, 2018 IRC. Update note #1 on sheet #6. 2. Show the smoke alarm circuit on the panel schedule, R314. 3. Notate interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.16. If you have any questions, please contact: Ken Van Karsen (520) 837-4912 City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/pdsd |
||
| 07/11/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |