Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
6113 S DUNTON AV
Address NEW:
6113 S DUNTON AV
Apply Date:
05/15/2026
Applicant:
Estanislao Soto
Description:
Renovate SFR

Permit Reviews

Permit Number - TC-RES-0526-02565
Permit Status: Inspections
Permit Description: Renovate SFR
Start Date Submittal Complete Date Status  
06/30/2026 RESIDENTIAL ADD/ALT v.2 07/10/2026 APPROVED Review Details
07/10/2026 ADMINISTRATIVE v.1 07/10/2026 REQUIRES RESUBMIT Review Details
05/19/2026 RESIDENTIAL ADD/ALT v.1 05/29/2026 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0526-02565
Permit Status: Inspections
Permit Description: Renovate SFR
Date Description Comments
05/19/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0526-02565
Permite Description: Renovate SFR
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
07/21/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 7/21/26: nail plates required throughout at any plumbing/mechanical/electrical that come within 1 1/4" from face of stud, properly secure NM cable 12" from box, NM cable must be replaced at kitchen island, gas piping at island must have conduit terminate no less than 2" above finish floor, R-8 flex required throughout for ductwork, dryer vent missing at time of inspection, smoke detector must be 3' from bathroom and supply/return air, proper support DWV in wall and Pex piping in wall, proper nail plates for DWV required throughout, drain pan required at air handler in attic, clear floor space required for attic access, seal all penetrations going through top plate and exterior wall. STOPPED INSPECTION MORE ITEMS MAY BE ADDED.Gas pressure test and underground plumbing have been approved on permit (TC-RES-0524-02778)

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
OBA-OBA-TC-RES-0526-02565_V1.PDF DOCUMENTS VIEW
REVISION 2_NARATIVE_V1.PDF DOCUMENTS VIEW
REVISION 2_SET_V1.PDF DOCUMENTS VIEW