Permit: TC-RES-0225-00759
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
10527 E PLACITA LOS REYES
Address NEW:
10527 E PLACITA LOS REYES
Apply Date:
02/10/2025
Applicant:
Carlos Canez
Description:
Renovate SFR and Bedroom Suite & Garage Addition
Permit Reviews
Permit Number - TC-RES-0225-00759
Permit Status: Complete
Permit Description: Renovate SFR and Bedroom Suite & Garage Addition
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/24/2025 | RESIDENTIAL NEW DWELLING v.1 | 04/15/2025 | REQUIRES RESUBMIT |
| 10/28/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/29/2025 | APPROVED |
| 04/25/2025 | RESIDENTIAL NEW DWELLING v.3 | 05/20/2025 | REQUIRES RESUBMIT |
| 05/21/2025 | RESIDENTIAL NEW DWELLING v.4 | 05/22/2025 | APPROVED |
| 04/24/2025 | RESIDENTIAL NEW DWELLING v.2 | 04/24/2025 | REQUIRES RESUBMIT |
| 05/22/2025 | RESTAMP - RESIDENTIAL v.1 | 05/27/2025 | APPROVED |
Conditions
Permit Number - TC-RES-0225-00759
Permit Status: Complete
Permit Description: Renovate SFR and Bedroom Suite & Garage Addition
| Date | Description | Comments |
|---|---|---|
| 02/24/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/owner-builder-affidavit_020625.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 03/20/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0225-00759
Permite Description: Renovate SFR and Bedroom Suite & Garage Addition
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 1-Finish piping by furnace room. 2-Provide test for gas piping. 3-Sub-panel is not located per approved plans. 4-Nail protection at plates is not per Code. |
| 08/04/2025 | COT - RSBU - Interior Shear Bracing | N/A | Not Ready | Not ready, currently at demo. |
| 06/06/2025 | COT - RSPL - Sewer | N/A | Partial Pass | 6/6/25 1. Plumbing not per plan. Contractor will get plan revised, proceed at own risk. If plans are not revised contractor will have to change plumbing to 4". |
| 09/17/2025 | COT - RSBU - Preslab | N/A | Partial Pass | |
| 06/03/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 08/04/2025 | RSBU - Building Progress | N/A | Canceled | |
| 06/03/2026 | COT - RSPL - Rough Soil | N/A | Not Applicable | duplicate |
| 06/03/2026 | RSBU - Building Final | N/A | Re-inspection required | Clean outs must be glued shut, anti tip device required at stove, hammer arrestors needed at dishwasher and washing machine, washer/dryer out must be GFCI protected, garbage disposal must be GFCI protected, all hose bibs needed anti siphon devices, all external condensate lines shall have a 90 pointing to ground, all external pvc shall be painted |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0225-00759
Permit Description: Renovate SFR and Bedroom Suite & Garage Addition
Total Completed Inspections - 16