| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 1-Finish piping by furnace room. 2-Provide test for gas piping. 3-Sub-panel is not located per approved plans. 4-Nail protection at plates is not per Code. |
|
| 12/19/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 12/19/25 move or block pex lines that are within 12" or recessed lights, insulate pex lines in garage, add straps to loose vent pipes at kitchen and bathroom, fire foam at ac lines through top plate. Other issues have been fixed, gas test complete | |
| 12/23/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 12/23/25 corrections made ok to insulate and drywall |