Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - TC-RES-0225-00759
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/24/2025 | Site Zoning - Standard | APPROVED | |||
| 03/28/2025 | Site Engineering - Standard | NOT REQUIRED | |||
| 04/15/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/15/2025 | Fire New Construction - Standard | REQUIRES RESUBMIT | Clarify the following for Fire Sprinklers-Fire Hydrant requirements: 1. Construction drawings page A-101 indicates 2897 square feet for dwelling size and 3013 Square feet for addition, equals to 5910 Square feet. 2. Structural calculation's page A-101 Indicates a total of 3976 Square feet for the structure including addition. Please clarify. sal.erivezjr@tucsonaz.gov |
||
| 03/20/2025 | Residential Building - Standard | REQUIRES RESUBMIT | TC-RES-0225-00759 PLAN REVIEW COMMENTS Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide a separate Comment Response Letter when submitting updated plans. Facilitate a shorter back check time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment revisions. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2018 International Residential Code and 2018 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. PROVIDE A COMPLETE PLAN SET showing all proposed alterations to the building with 2018 IRC code compliance. Provide a response letter addressing each comment with location of change on the plans. Submit separate letter and plan set files. PLANS: 1. The Solor Photovoltaic system reinstallation requires a separate permit with current code compliance, R106.1.1. Update keynote #2 sheet D101. SECTIONS - DETAILS: 1. An unvented roof assembly requires an air-impermeable rigid insulation material with a minimum R-5 value applied correctly to either side of the roof sheathing, R806.5. Show a roof design with insulation types and minimum thickness for meeting the condensation control requirement and the minimum total insulation value of R-38. Clarify detail #5 sheet S103 and sheet S202 details showing the air-impermeable rigid insulation material adhered to either side of the roof sheathing and the batt insulation in contact with the roof material. ELECTRICAL PLANS: 1. Interior 15A & 20A circuits serving outlet locations (except garage, kitchen, and bathrooms) including receptacles, lights, and smoke detectors require combination type arc-fault circuit interrupters, E3902.16. Add notation to the lighting circuits #3 & 6. If you have any questions, please contact: PDSD-Residential@tucsonaz.gov City of Tucson Residential Plan Review Submit a corrected plan set at https://www.tucsonaz.gov/Departments/Planning-Development-Services ---------------------- |
||
| 02/24/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |