Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
3353 N FORGEUS AV
Apply Date:
02/05/2024
Applicant:
alex enoch
Description:
SFR Remodel and Bedroom Suite Addition

Permit Reviews

Permit Number - TC-RES-0224-00659
Permit Status: Complete
Permit Description: SFR Remodel and Bedroom Suite Addition
Start Date Submittal Complete Date Status  
03/05/2024 RESIDENTIAL NEW DWELLING v.2 04/25/2024 REQUIRES RESUBMIT Review Details
06/21/2024 RESTAMP - RESIDENTIAL v.1 06/21/2024 APPROVED Review Details
01/31/2025 RESIDENTIAL NEW DWELLING REVISION v.1 03/04/2025 APPROVED Review Details
06/21/2024 RESIDENTIAL NEW DWELLING v.4 06/21/2024 APPROVED Review Details
08/16/2024 RESIDENTIAL NEW DWELLING v.2 09/17/2024 APPROVED Review Details
10/18/2024 RESIDENTIAL NEW DWELLING REVISION v.1 11/20/2024 APPROVED Review Details
02/06/2024 RESIDENTIAL NEW DWELLING v.1 03/04/2024 REQUIRES RESUBMIT Review Details
08/15/2024 RESIDENTIAL NEW DWELLING v.1 08/16/2024 REQUIRES RESUBMIT Review Details
03/19/2026 BUILDING DEFERRED SUBMITTAL REVIEW v.1 03/20/2026 APPROVED Review Details
05/30/2024 RESIDENTIAL NEW DWELLING v.3 06/20/2024 REQUIRES RESUBMIT Review Details
03/25/2025 RESIDENTIAL NEW DWELLING REVISION v.1 04/23/2025 APPROVED Review Details
09/19/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/23/2025 APPROVED Review Details

Conditions

Permit Number - TC-RES-0224-00659
Permit Status: Complete
Permit Description: SFR Remodel and Bedroom Suite Addition
Date Description Comments
04/21/2025 Manual J report
02/14/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0224-00659
Permite Description: SFR Remodel and Bedroom Suite Addition
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
01/22/2025 COT - RSEL - Electrical Underground N/A Not Applicable
04/15/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 15 April 25
1. Pancake boxes overloaded, no more than 6 Cubic inches.
2. Interior outlets are on the same circuits as exterior.
3. Hall bath bidet outlet too close to bathtub, needs to be 36" away minimum.
4. Hallway bath is missing Lav outlet.
09/22/2025 COT - RSPL - Plumbing Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0224-00659
Permit Description: SFR Remodel and Bedroom Suite Addition
Total Completed Inspections - 15
Date Description Inspector Results Comments
10/31/2024 COT - RSPL - Rough Soil Passed
11/06/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
11/06/2024 COT - RSBU - Preslab Passed
01/22/2025 COT - RSEL - Grounding/Bonding Passed
01/22/2025 BULD - Electrical Clearance Passed
02/19/2025 COT - RSBU - Roof Nailing Passed
02/19/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
04/15/2025 COT - RSPL - Gas Pressure Test Passed
04/15/2025 COT - RSPL - Yard Water Line Passed
09/22/2025 COT - RSEL - Electrical Final Passed
09/22/2025 COT - RSME - Mechanical Final Passed
09/22/2025 COT - RSEL - Outdoor Lighting Passed
09/29/2025 COT - BULD - SWG Clearance Passed 9.29.2025
Clearance to SW Gas.
02/27/2026 COT - RSPL - Plumbing Final Passed
03/09/2026 RSBU - Building Final Passed 3.9.26
Corrections made, approved

Documents

File Name Document Type  
LOFC_LETTEROFCOMPLETION (SSRS).PDF DOCUMENTS VIEW
KURICK - ROBINSON MANUAL J S_V1.PDF DOCUMENTS VIEW
SUBMIT HVAC LEAK TEST-2025-09-19_V1.PDF DOCUMENTS VIEW
SUBMIT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
REV NARRATIVE_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
TC-RES-0224-00659 REV 3 - JAN 24 2025_V1.PDF DOCUMENTS VIEW
TC-RES-0224-00659 FOOTING DETAIL_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
NARRATIVE OF REVISIONS TO PERMIT TC-RES-0224-00659_V2.PDF DOCUMENTS VIEW
REV 1_1 TC-RES-0224-00659_V2.PDF DOCUMENTS VIEW
3353 N FORGEUS AVE MANUAL D MC1_V1.PDF DOCUMENTS VIEW
3353 N FORGEUS AVE MANUAL J S MC1_V1.PDF DOCUMENTS VIEW
3353 N FORGEUS AVE TRUSS CALCS_V1.PDF DOCUMENTS VIEW
3353 N FORGEUS AVE TRUSS LAYOUT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-3353 N FORGEUS AVE CONSTRUCTION DOCUMENT CD1_V1 (2)_V1.PDF DOCUMENTS VIEW
OWNER_BUILDER AFFIDAVIT._V2.PDF DOCUMENTS VIEW
DDO DECISION.PDF SPECIAL APPLICATIONS VIEW
DDO NOTICE AND MAP - FORGEUS.PDF SPECIAL APPLICATIONS VIEW
DDO APPLICATION AND PLANS.PDF SPECIAL APPLICATIONS VIEW