Permit: TC-RES-0123-02047
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
1606 W SAUVIGNON DR
Address NEW:
1606 W SAUVIGNON DR
Apply Date:
01/12/2023
Applicant:
BRANDY PALCHETTI
Description:
• SYSTEM SIZE: 8500W DC, 6000W AC • MODULES: (25) JA SOLAR: JAM60S10-340/MR • INVERTERS: (25) ENPHASE ENERGY: IQ7-60-2-US • RACKING: ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING SNR-DC-00438 • EXISTING SOLAR SYSTEM INSTALLED. • MAIN BREAKER DERATE: REPLACE EXISTING 100A MAIN BREAKER WITH NEW 90 AMP MAIN BREAKER
Permit Reviews
Permit Number - TC-RES-0123-02047
Permit Status: Complete
Permit Description: • SYSTEM SIZE: 8500W DC, 6000W AC
• MODULES: (25) JA SOLAR: JAM60S10-340/MR
• INVERTERS: (25) ENPHASE ENERGY: IQ7-60-2-US
• RACKING: ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING
SNR-DC-00438
• EXISTING SOLAR SYSTEM INSTALLED.
• MAIN BREAKER DERATE: REPLACE EXISTING 100A MAIN
BREAKER WITH NEW 90 AMP MAIN BREAKER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/13/2023 | RESIDENTIAL SOLAR v.1 | 07/04/2023 | APPROVED |
| 04/27/2023 | RESIDENTIAL SOLAR v.1 | 05/18/2023 | APPROVED |
| 01/13/2023 | RESIDENTIAL SOLAR v.1 | 01/31/2023 | APPROVED |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0123-02047
Permite Description: • SYSTEM SIZE: 8500W DC, 6000W AC
• MODULES: (25) JA SOLAR: JAM60S10-340/MR
• INVERTERS: (25) ENPHASE ENERGY: IQ7-60-2-US
• RACKING: ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING
SNR-DC-00438
• EXISTING SOLAR SYSTEM INSTALLED.
• MAIN BREAKER DERATE: REPLACE EXISTING 100A MAIN
BREAKER WITH NEW 90 AMP MAIN BREAKER
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/19/2023 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 06/01/2023 | BULD - Electrical Clearance | N/A | Not Ready | 4/13/23 - Partial for meter adapter, DGL Clearance was called into TEP at 1:35 (power-kill) 4/19/23 - NR cancelled by field tech. Plans must be revised, approved by the City of Tucson and posted on site - TG 6/1/23: NR cancelled by field tech. Plans must be revised, approved by City of Tucson |
| 06/01/2023 | RSBU - Building Final | N/A | Not Ready | 4/19/23 - NR cancelled by field tech. Plans must be revised, approved by the City of Tucson and posted on site - TG 6/1/23: NR cancelled by field tech. Plans must be revised, approved by City of Tucson |
| 06/01/2023 | COT - RSEL - Electrical Final | N/A | Not Ready | 4/13/23 - Partial for meter adapter, DGL Clearance was called into TEP at 1:35 (power-kill) 4/19/23 - NR cancelled by field tech. Plans must be revised, approved by the City of Tucson and posted on site - TG 6/1/23: NR cancelled by field tech. Plans must be revised, approved by City of Tucson |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0123-02047
Permit Description: • SYSTEM SIZE: 8500W DC, 6000W AC
• MODULES: (25) JA SOLAR: JAM60S10-340/MR
• INVERTERS: (25) ENPHASE ENERGY: IQ7-60-2-US
• RACKING: ULTRA RAIL SPEEDSEAL FOOT, SEE DRAWING
SNR-DC-00438
• EXISTING SOLAR SYSTEM INSTALLED.
• MAIN BREAKER DERATE: REPLACE EXISTING 100A MAIN
BREAKER WITH NEW 90 AMP MAIN BREAKER
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/27/2023 | BULD - Electrical Clearance | Passed | Clearance for TEP DGC/DGL. 7/27/2023 | |
| 07/27/2023 | RSBU - Building Final | Passed | Approved. Corrections have been made. Revisions have been submitted. 7/27/2023 | |
| 07/27/2023 | COT - RSEL - Electrical Final | Passed | Approved. Corrections have been made. Revisions have been submitted. 7/27/2023 |