Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
3257 E 30TH ST
Address NEW:
3257 E 30TH ST
Apply Date:
01/10/2023
Applicant:
Albert Abbott
Description:
Convert Carport to Workshop - Bathroom Addition

Permit Reviews

Permit Number - TC-RES-0123-02003
Permit Status: Inspections
Permit Description: Convert Carport to Workshop - Bathroom Addition
Start Date Submittal Complete Date Status  
01/17/2023 RESIDENTIAL NEW DWELLING v.1 02/08/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-0123-02003
Permit Status: Inspections
Permit Description: Convert Carport to Workshop - Bathroom Addition
Date Description Comments
06/15/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0123-02003
Permite Description: Convert Carport to Workshop - Bathroom Addition
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
06/13/2025 COT - RSPL - Yard Water Line N/A Partial Pass Depth of trenching is correct. Recall inspection when water line is in place.
10/19/2026 RSBU - Building Final N/A Not Ready Properly label panel due to miss labeled. Provide WR receptacles at all outdoor locations. Complete tie in at dryer. Provide GFCI receptacle for washer. Outdoor receptacle all tied into same circuit as inside. Both outdoor shall be dedicated. Provide a dedicated circuit for mini split circuit. Per manufacturer specifications. Screw disconnect box due to loose lid. Extend condensation line and secure to wall. Secure mini split to pad. Properly provide protection to line sets and seal off penetration. Provide clamp within 12” from disconnect. Provide vacuum breaker at hose bib. Ensure door handle meet ada requirements along with threshold. 10/19/2026
10/19/2026 COT - RSEL - Electrical Final N/A Not Ready Properly label panel due to miss labeled. Provide WR receptacles at all outdoor locations. Complete tie in at dryer. Provide GFCI receptacle for washer. Outdoor receptacle all tied into same circuit as inside. Both outdoor shall be dedicated. Provide a dedicated circuit for mini split circuit. Per manufacturer specifications. Screw disconnect box due to loose lid. Extend condensation line and secure to wall. Secure mini split to pad. Properly provide protection to line sets and seal off penetration. Provide clamp within 12” from disconnect. Provide vacuum breaker at hose bib. Ensure door handle meet ada requirements along with threshold. 10/19/2026
10/19/2026 COT - RSME - Mechanical Final N/A Not Ready Properly label panel due to miss labeled. Provide WR receptacles at all outdoor locations. Complete tie in at dryer. Provide GFCI receptacle for washer. Outdoor receptacle all tied into same circuit as inside. Both outdoor shall be dedicated. Provide a dedicated circuit for mini split circuit. Per manufacturer specifications. Screw disconnect box due to loose lid. Extend condensation line and secure to wall. Secure mini split to pad. Properly provide protection to line sets and seal off penetration. Provide clamp within 12” from disconnect. Provide vacuum breaker at hose bib. Ensure door handle meet ada requirements along with threshold. 10/19/2026
10/19/2026 COT - RSPL - Plumbing Final N/A Not Ready Properly label panel due to miss labeled. Provide WR receptacles at all outdoor locations. Complete tie in at dryer. Provide GFCI receptacle for washer. Outdoor receptacle all tied into same circuit as inside. Both outdoor shall be dedicated. Provide a dedicated circuit for mini split circuit. Per manufacturer specifications. Screw disconnect box due to loose lid. Extend condensation line and secure to wall. Secure mini split to pad. Properly provide protection to line sets and seal off penetration. Provide clamp within 12” from disconnect. Provide vacuum breaker at hose bib. Ensure door handle meet ada requirements along with threshold. 10/19/2026

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0123-02003
Permit Description: Convert Carport to Workshop - Bathroom Addition
Total Completed Inspections - 3
Date Description Inspector Results Comments
05/17/2024 COT - RSPL - Rough Soil Passed
02/27/2026 COT - RSPL - Yard Water Line Passed 2.27.26
Approved
03/09/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 3-9-26: all corrections made. Residential intermediates approved-okay to continue with construction.

Documents

File Name Document Type  
ALBERT K ABBOTT OWNER BUILDER AFFIDAVIT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-PLANS SUB 1_V1.PDF DOCUMENTS VIEW