Permit: TC-MDP-1224-01366
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
3942 E ELMWOOD ST
Address NEW:
3942 E ELMWOOD ST
Apply Date:
12/09/2024
Applicant:
Jesus Lozano
Description:
model plan template SFR (Model master plan TC-MDP-1024-01263)
Permit Reviews
Permit Number - TC-MDP-1224-01366
Permit Status: Inspections
Permit Description: model plan template SFR (Model master plan TC-MDP-1024-01263)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/07/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 | 02/25/2025 | REQUIRES RESUBMIT |
| 02/27/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.4 | 03/26/2025 | REQUIRES RESUBMIT |
| 12/17/2024 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 | 01/13/2025 | REQUIRES RESUBMIT |
| 03/26/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.5 | 03/27/2025 | APPROVED |
| 01/24/2025 | SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 | 02/06/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-MDP-1224-01366
Permit Status: Inspections
Permit Description: model plan template SFR (Model master plan TC-MDP-1024-01263)
| Date | Description | Comments |
|---|---|---|
| 03/26/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 12/06/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 12/06/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-1224-01366
Permite Description: model plan template SFR (Model master plan TC-MDP-1024-01263)
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | Provide address on site. Provide Approved plans on site prior to inspection. 4/28/2025 |
| 04/29/2025 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | Anchor bolts are loose throughout. Add shot pins at marked areas interior bottom plates. Missing bracing at both A1 and A4 trusses per truss calcs. Loose sheathing at shower in primary bath. Perimeter nailing not per schedule at window in flex room. A7.0 detail 206, 207, and 213 not per plan. 4/29/2025 |
| 05/06/2025 | RSBU - Building Progress | N/A | Not Applicable | |
| 05/09/2025 | COT - RSBU - Interior Shear Bracing | N/A | Re-inspection required | Partial inspection only; Install shear panels for BWL B. For partial approval; balance after drywall is installed. |
| 05/06/2025 | COT - RSBU - Masonry Pregrout | N/A | Partial Pass | 1st lift |
| 06/02/2025 | COT - RSPL - Sewer | N/A | Partial Pass | Partial pass. Sewer lines to second clean outs approved. Okay to backfill progress areas. Shading required. Pending tie into main sewer line. 6/2/2025 |
| 09/18/2025 | COT - RSEL - Electrical Final | N/A | Not Ready | |
| 09/18/2025 | COT - RSPL - Plumbing Final | N/A | Not Ready | |
| 10/22/2025 | COT - BULD - SWG Clearance | N/A | Not Ready | unable to access unit |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-1224-01366
Permit Description: model plan template SFR (Model master plan TC-MDP-1024-01263)
Total Completed Inspections - 12
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/28/2025 | COT - RSPL - Rough Soil | Passed | Plumbing per plan, ok to backfill 3/28/25 | |
| 04/02/2025 | COT - RSBU - Preslab | Passed | Ensure slab area is termite treated. | |
| 04/29/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Approved per Robert Chandler on clip nail/ roof nailing. Jim Burge for intermediate. Reference to Tc-res-1223-10006. 4/29/2025 | |
| 05/06/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 05/06/2025 | COT - RSBU - Roof Nailing | Passed | ||
| 05/20/2025 | COT - RSBU - Masonry Pregrout | Passed | ||
| 06/02/2025 | COT - RSPL - Yard Water Line | Passed | Okay to backfill. Shading required. 6/2/2025 | |
| 06/26/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 07/14/2025 | COT - RSPL - Sewer | Passed | 7/14/25 Pass, shading required. |
|
| 09/18/2025 | BULD - Electrical Clearance | Passed | ||
| 09/18/2025 | COT - RSEL - Electrical Underground | Passed | ||
| 09/18/2025 | COT - RSEL - Grounding/Bonding | Passed | 9.18.25 APPROVED |