Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Address NEW:
3942 E ELMWOOD ST
Apply Date:
12/09/2024
Applicant:
Jesus Lozano
Description:
model plan template SFR (Model master plan TC-MDP-1024-01263)

Permit Reviews

Permit Number - TC-MDP-1224-01366
Permit Status: Inspections
Permit Description: model plan template SFR (Model master plan TC-MDP-1024-01263)
Start Date Submittal Complete Date Status  
02/07/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.3 02/25/2025 REQUIRES RESUBMIT Review Details
02/27/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.4 03/26/2025 REQUIRES RESUBMIT Review Details
12/17/2024 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 01/13/2025 REQUIRES RESUBMIT Review Details
03/26/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.5 03/27/2025 APPROVED Review Details
01/24/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 02/06/2025 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-MDP-1224-01366
Permit Status: Inspections
Permit Description: model plan template SFR (Model master plan TC-MDP-1024-01263)
Date Description Comments
03/26/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
12/06/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
12/06/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-1224-01366
Permite Description: model plan template SFR (Model master plan TC-MDP-1024-01263)
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
04/28/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required Provide address on site. Provide Approved plans on site prior to inspection. 4/28/2025
04/29/2025 COT - RSBU - Roof Nailing N/A Re-inspection required Anchor bolts are loose throughout. Add shot pins at marked areas interior bottom plates. Missing bracing at both A1 and A4 trusses per truss calcs. Loose sheathing at shower in primary bath. Perimeter nailing not per schedule at window in flex room. A7.0 detail 206, 207, and 213 not per plan. 4/29/2025
05/06/2025 RSBU - Building Progress N/A Not Applicable
05/09/2025 COT - RSBU - Interior Shear Bracing N/A Re-inspection required Partial inspection only; Install shear panels for BWL B. For partial approval; balance after drywall is installed.
05/06/2025 COT - RSBU - Masonry Pregrout N/A Partial Pass 1st lift
06/02/2025 COT - RSPL - Sewer N/A Partial Pass Partial pass. Sewer lines to second clean outs approved. Okay to backfill progress areas. Shading required. Pending tie into main sewer line. 6/2/2025
09/18/2025 COT - RSEL - Electrical Final N/A Not Ready
09/18/2025 COT - RSPL - Plumbing Final N/A Not Ready
10/22/2025 COT - BULD - SWG Clearance N/A Not Ready unable to access unit

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-1224-01366
Permit Description: model plan template SFR (Model master plan TC-MDP-1024-01263)
Total Completed Inspections - 12
Date Description Inspector Results Comments
03/28/2025 COT - RSPL - Rough Soil Passed Plumbing per plan, ok to backfill 3/28/25
04/02/2025 COT - RSBU - Preslab Passed Ensure slab area is termite treated.
04/29/2025 COT - RSBU - Excavation/Rebar/Zoning Passed Approved per Robert Chandler on clip nail/ roof nailing. Jim Burge for intermediate. Reference to Tc-res-1223-10006. 4/29/2025
05/06/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
05/06/2025 COT - RSBU - Roof Nailing Passed
05/20/2025 COT - RSBU - Masonry Pregrout Passed
06/02/2025 COT - RSPL - Yard Water Line Passed Okay to backfill. Shading required. 6/2/2025
06/26/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
07/14/2025 COT - RSPL - Sewer Passed 7/14/25
Pass, shading required.
09/18/2025 BULD - Electrical Clearance Passed
09/18/2025 COT - RSEL - Electrical Underground Passed
09/18/2025 COT - RSEL - Grounding/Bonding Passed 9.18.25
APPROVED

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW