Start Date Submittal Complete Date Status  
01/14/2026 BUILDING DEFERRED SUBMITTAL REVIEW v.1 01/14/2026 APPROVED Review Details
01/15/2025 SITE FROM MODEL PERMIT - SUBDIVISION v.3 01/16/2025 APPROVED Review Details
12/17/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 12/19/2025 APPROVED Review Details
12/23/2024 SITE FROM MODEL PERMIT - SUBDIVISION v.2 01/02/2025 REQUIRES RESUBMIT Review Details
01/16/2025 RESTAMP - RESIDENTIAL v.1 01/17/2025 APPROVED Review Details
12/04/2024 SITE FROM MODEL PERMIT - SUBDIVISION v.1 12/14/2024 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-MDP-1124-01344
Permit Status: Complete
Permit Description: SFR 2 Story (Model master plan TC-MDP-1024-01150)
Date Description Comments
11/21/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
12/18/2025 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
11/21/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
11/21/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
11/21/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-1124-01344
Permite Description: SFR 2 Story (Model master plan TC-MDP-1024-01150)
Total Outstanding Inspections - 12
Last Inspection Date Description Inspector Results Comments
05/16/2025 COT - RSBU - Excavation/Rebar/Zoning N/A Not Ready 5-16-25, not ready.
05/16/2025 COT - RSBU - Preslab N/A Not Ready 5-16-25, not ready.
09/24/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required (with fee) 9-24-25: add shot pins within 6" at the end of each sill plate, wrong straps used at post to beams-CS16 straps are required, 8-16D nails are required at the garage top plate splice, missing A34'S-see A6 Box Header detail, Screws/ nails at SW2 not per plan throughout, also exterior sheathing contains numerous over penetrated nails-add nails to sheathing where over penetrated more than 1/16", add nails on 2nd floor sill to decking-shear walls add 4 nails per cell and 2 for non-shear walls.
12/17/2025 COT - RSEL - Electrical Final N/A Canceled 12/17/2025
Canceled per contractor.
12/17/2025 COT - RSEL - Outdoor Lighting N/A Canceled 12/17/2025
Canceled per contractor.
12/17/2025 COT - RSME - Mechanical Final N/A Canceled 12/17/2025
Canceled per contractor.
01/08/2026 COT - RSPL - Gas Pressure Test N/A Not Applicable
12/17/2025 COT - RSPL - Plumbing Final N/A Canceled 12/17/2025
Canceled per contractor.
09/24/2025 RSBU - Building Progress N/A Re-inspection required 9-24-25: see clips/sheathing notes
01/08/2026 ENGR Engineering Final N/A Not Ready
12/17/2025 RSBU - Building Final N/A Canceled 12/17/2025
Canceled per contractor.
01/13/2026 COT - BULD - SWG Clearance N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-1124-01344
Permit Description: SFR 2 Story (Model master plan TC-MDP-1024-01150)
Total Completed Inspections - 19
Date Description Inspector Results Comments
05/09/2025 COT - RSPL - Sewer Passed
05/13/2025 COT - RSEL - Electrical Underground Passed 5-13-25, verified depth at 18" together with Schedule 40 electrical conduit in place. Okay to backfill.
05/19/2025 COT - RSBU - Excavation/Rebar/Zoning Passed 5-19-25, excavation/rebar/setbacks verified as per plans. Okay to pour concrete.
05/19/2025 COT - RSBU - Preslab Passed 5-19-25, preslab,excavation/rebar/setbacks verified as per plans. Okay to pour concrete
09/23/2025 COT - RSBU - Roof Nailing Passed 9.23.25
Approved
10/01/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
10/09/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
10/14/2025 BULD - Electrical Clearance Passed 10-14-25: okay to energize panel. ECO clearance sent to TEP.
10/14/2025 COT - RSEL - Grounding/Bonding Passed 10-14-25: verified UFER-no water/gas bonding required.
10/20/2025 COT - RSBU - Interior Shear Bracing Passed 10-20-25: okay to tape & texture drywall.
11/03/2025 COT - RSPL - Yard Water Line Passed 11-3-25: main water line approved. Okay to backfill with shading materials.
01/08/2026 COT - RSEL - Electrical Final Passed
01/08/2026 COT - RSEL - Outdoor Lighting Passed
01/08/2026 COT - RSME - Mechanical Final Passed
01/08/2026 COT - RSPL - Plumbing Final Passed
01/08/2026 COT - RSPL - Rough Soil Passed
01/08/2026 RSBU - Building Progress Passed
01/13/2026 ENGR Engineering Final Passed
01/13/2026 RSBU - Building Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL (SSRS).PDF DOCUMENTS VIEW
240792 RODEO ADDITION NO4 LOTS 9 - 10 PT-2025-12-15_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
HABITAT RODEO VILLAGE LOT 9 5417 S. IDA LN PLOT PLAN 10.14.24_V2.PDF DOCUMENTS VIEW