Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-1123-01843
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
10186 S ARNOLD RANCH CT
Address NEW:
10186 S ARNOLD RANCH CT
Apply Date:
11/28/2023
Applicant:
Description:
SFR RKK35G T21-M0090
Permit Reviews
Permit Number - TC-MDP-1123-01843
Permit Status: Inspections complete
Permit Description: SFR RKK35G T21-M0090
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/14/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 06/17/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1123-01843
Permit Status: Inspections complete
Permit Description: SFR RKK35G T21-M0090
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 06/14/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 06/14/2024 | Post-Installed Anchor Inspection Report is required. |
| 06/14/2024 | Post-Tension Inspection Report is required. |
| 06/14/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-1123-01843
Permit Status: Inspections complete
Permit Description: SFR RKK35G T21-M0090
| Date | Description | Comments |
|---|---|---|
| 11/28/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 06/14/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01843
Permite Description: SFR RKK35G T21-M0090
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2024 | BULD - Electrical Clearance | N/A | Re-inspection required | Missing temp WR receptacle, breaker and UFER. 8/20/2024 |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01843
Permit Description: SFR RKK35G T21-M0090
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2024 | COT - RSPL - Rough Soil | Passed | ||
| 07/11/2024 | COT - RSPL - Sewer | Passed | ||
| 07/11/2024 | COT - RSPL - Yard Water Line | Passed | ||
| 07/19/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 07/22/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 7/22/24: Concrete forms are set, post tension cabling is evenly spaced, all required rebar reinforcement is installed, Ufer ground is installed in footing on garage wall, masa clips are attached to the form, underground electrical conduit is installed for kitchen island and all plumbing pipes are properly wrapped with foam wrap. Okay to pour concrete. | |
| 07/22/2024 | COT - RSBU - Preslab | Passed | 7/22/24: Concrete forms are set, post tension cabling is evenly spaced, all required rebar reinforcement is installed, Ufer ground is installed in footing on garage wall, masa clips are attached to the form, underground electrical conduit is installed for kitchen island and all plumbing pipes are properly wrapped with foam wrap. Okay to pour concrete. | |
| 07/22/2024 | COT - RSEL - Grounding/Bonding | Passed | 7/22/24: Concrete forms are set, post tension cabling is evenly spaced, all required rebar reinforcement is installed, Ufer ground is installed in footing on garage wall, masa clips are attached to the form, underground electrical conduit is installed for kitchen island and all plumbing pipes are properly wrapped with foam wrap. Okay to pour concrete. | |
| 08/14/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Shear wall hold down are properly secured with nails and interior shear walls are secured with nails and titan bolts to the concrete floor. Plywood sheathing on shear walls are properly secured with nails per plan requirements. Exterior and interior walls are secured to concrete floor with masa clips, titan bolts, j-bolts, or shot pins. All straps are properly placed and secured with nails. Diagonal bracing is properly installed and nailed to each stud. Okay to proceed with rough-in work. | |
| 08/14/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly installed and nailed to top plate, all trusses have H2.5 clips nailed to them. Plywood sheathing is properly secured to roof trusses with nails per plan and code requirements. Okay to proceed with rough-in work. | |
| 08/29/2024 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. 8/29/2024 | |
| 09/11/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with insulation and drywall installation. | |
| 09/11/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line is under 15 psi of air pressure with no leaks. Okay to proceed | |
| 10/01/2024 | COT - RSBU - Interior Shear Bracing | Passed | 10-1-24, inspected and approved interior shear wall. Okay to tape and texture. | |
| 11/21/2024 | COT - BULD - SWG Clearance | Passed | 11-21-24, approved for Southwest gas connection. | |
| 12/05/2024 | COT - RSEL - Electrical Final | Passed | 12-5-24, electrical final approved. | |
| 12/05/2024 | COT - RSEL - Outdoor Lighting | Passed | 12-5-24, outdoor lighting final approved. | |
| 12/10/2024 | COT - RSPL - Plumbing Final | Passed | 12-10-24, plumbing final approved. | |
| 12/10/2024 | COT - RSME - Mechanical Final | Passed | 12-10-24, mechanical final approved. | |
| 12/12/2024 | RSBU - Building Final | Passed | 12-12-24, building final approved. | |
| 12/12/2024 | ENGR Engineering Final | Passed | ||
| 12/13/2024 | RSBU - Building Progress | Passed |