Permit: TC-MDP-1123-01826
Permit Details
Apply Date:
04/02/2024
Applicant:
Celina Rodriguez
Description:
SFR BT1465-130 T22-M0011
Permit Reviews
Permit Number - TC-MDP-1123-01826
Permit Status: Issued
Permit Description: SFR BT1465-130 T22-M0011
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/04/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 04/11/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1123-01826
Permit Status: Issued
Permit Description: SFR BT1465-130 T22-M0011
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
04/11/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
04/11/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
04/11/2024 | Post-Tension Inspection Report is required. |
04/11/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
04/11/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
11/22/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-1123-01826
Permit Status: Issued
Permit Description: SFR BT1465-130 T22-M0011
Date | Description | Comments |
---|---|---|
11/21/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
11/22/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-1123-01826
Permit Description: SFR BT1465-130 T22-M0011
Total Completed Inspections - 15
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/26/2024 | COT - RSPL - Backwater Valve | Passed | Underground plumbing is complete from double clean outs and backwater valve to all fixture locations in the house. Green tracer wire is installed from clean outs to the end of sewer pipe, not connected to the main sewer system at this point in time. | |
04/26/2024 | COT - RSPL - Yard Water Line | Passed | Main Water Line is under 65# of air pressure and holding without leaking. Okay to shade pipe and backfill trench. | |
04/26/2024 | COT - RSPL - Rough Soil | Passed | Underground plumbing is complete from double clean outs and backwater valve to all fixture locations in the house. Green tracer wire is installed from clean outs to the end of sewer pipe, not connected to the main sewer system at this point in time. | |
05/08/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is properly installed per plans, additional rebar reinforcement is installed per plans, shear wall hold downs are in place, masa clips are in place, Ufer ground is installed on garage side footing, underground electrical for kitchen island is installed, and all underground slab plumbing pipes are properly wrapped for protection. Okay to pour concrete for footings and slab on grade. | |
05/08/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is properly installed per plans, additional rebar reinforcement is installed per plans, shear wall hold downs are in place, masa clips are in place, Ufer ground is installed on garage side footing, underground electrical for kitchen island is installed, and all underground slab plumbing pipes are properly wrapped for protection. Okay to pour concrete for footings and slab on grade. | |
05/08/2024 | COT - RSEL - Electrical Underground | Passed | Concrete forms are set, post tension cabling is properly installed per plans, additional rebar reinforcement is installed per plans, shear wall hold downs are in place, masa clips are in place, Ufer ground is installed on garage side footing, underground electrical for kitchen island is installed, and all underground slab plumbing pipes are properly wrapped for protection. Okay to pour concrete for footings and slab on grade. | |
05/08/2024 | COT - RSEL - Grounding/Bonding | Passed | Concrete forms are set, post tension cabling is properly installed per plans, additional rebar reinforcement is installed per plans, shear wall hold downs are in place, masa clips are in place, Ufer ground is installed on garage side footing, underground electrical for kitchen island is installed, and all underground slab plumbing pipes are properly wrapped for protection. Okay to pour concrete for footings and slab on grade. | |
06/12/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Plywood sheathing for exterior shear walls is properly secured to studs per plan requirements. All masa clips and shear wall hold downs are properly nailed to bottom plates and wall studs. Bottom plates are secured with cut nails, titan bolts, or j-bolts. Okay to proceed with plumbing top out. | |
06/12/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly secured to top plate with nails and H2.5 hurricane ties. Plywood sheathing is securely attached to trusses with nails per plan. Okay to proceed with plumbing top out. | |
07/17/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
07/19/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
08/09/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
09/11/2024 | COT - RSPL - Sewer | Passed | 9/11/24: Sewer is connected and under test. Okay to shade pipe and backfill trench. | |
09/16/2024 | BULD - Electrical Clearance | Passed | Passes electrical clearance ECO 9/16/2024 | |
10/08/2024 | COT - BULD - SWG Clearance | Passed | SWG for meter connection only |