Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 136301420


Addresses:

9129 E RED BLUFF CT


Inspection Status: Passed

Inspection History: COT - RSEL - Electrical Underground 

Permit Number - TC-MDP-1123-01826

Inspection Description - COT - RSEL - Electrical Underground 

Inspection Status - Passed

Date Description Inspector Results Comments
05/08/2024 COT - RSEL - Electrical Underground  Passed Concrete forms are set, post tension cabling is properly installed per plans, additional rebar reinforcement is installed per plans, shear wall hold downs are in place, masa clips are in place, Ufer ground is installed on garage side footing, underground electrical for kitchen island is installed, and all underground slab plumbing pipes are properly wrapped for protection. Okay to pour concrete for footings and slab on grade.