Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Apply Date:
11/08/2024
Applicant:
Dana Petty
Description:
SFR MERI132021 T21-M0062 (Model master plan TC-MDP-0223-00478)

Permit Reviews

Permit Number - TC-MDP-1024-01192
Permit Status: Complete
Permit Description: SFR MERI132021 T21-M0062 (Model master plan TC-MDP-0223-00478)
Start Date Submittal Complete Date Status  
09/12/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/15/2025 APPROVED Review Details
11/14/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 12/03/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-1024-01192
Permit Status: Complete
Permit Description: SFR MERI132021 T21-M0062 (Model master plan TC-MDP-0223-00478)
Date Description Comments
10/14/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
11/18/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
11/18/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
11/18/2024 Post-Tension Inspection Report is required.
10/14/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
10/14/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
11/18/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-1024-01192
Permit Description: SFR MERI132021 T21-M0062 (Model master plan TC-MDP-0223-00478)
Total Completed Inspections - 21
Date Description Inspector Results Comments
07/02/2025 COT - RSPL - Yard Water Line Passed Okay to backfill. Shading required. 7/2/2025
07/03/2025 COT - RSPL - Rough Soil Passed Approved. Okay to backfill. Shading required. 7/3/2025
07/03/2025 COT - RSPL - Sewer Passed Approved. Okay to backfill. Shading required. 7/3/2025
07/11/2025 COT - RSBU - Excavation/Rebar/Zoning Passed 7.11.25
Footer depth verified. Uffer verified. 3 inch clearance from rebar maintained throughout. Plumbing wrapped. Hold downs verified per plans. Diagonal rebar sections length and size verified per plans. Hold down depth verified. OK TO POUR.
07/11/2025 COT - RSBU - Preslab Passed 7.11.25
Footer depth verified. Uffer verified. 3 inch clearance from rebar maintained throughout. Plumbing wrapped. Hold downs verified per plans. Diagonal rebar sections length and size verified per plans. Hold down depth verified. OK TO POUR.
07/11/2025 COT - RSEL - Electrical Underground Passed 7-11-25: approved
07/23/2025 COT - RSBU - Roof Nailing Passed 7-21-25: add shot pins within 6" at the end of plate and 24" o.c. Thereafter, missing nails to RSP4 on south side, missing RSP4 on north & south ends of home, add nails to A-35's throughout, missing A-35's at south end of garage,south of kitchen island, back patio, and at north & south end of home, missing nails at garage shear panel-plans call for 6" o.c. at edges/joints, missing nails at exterior sheathing at garage-4" o.c., missing H-25 at truss CG48C, loose roof panels at southeast are of garage and at back patio, provide truss calculations, STOPPED INSPECTION-ADDITIONAL ITEMS MSY BE ADDED.

7.23.25
Satisfactory corrections made, no additional items found.
07/23/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 7-21-25: add shot pins within 6" at the end of plate and 24" o.c. Thereafter, missing nails to RSP4 on south side, missing RSP4 on north & south ends of home, add nails to A-35's throughout, missing A-35's at south end of garage,south of kitchen island, back patio, and at north & south end of home, missing nails at garage shear panel-plans call for 6" o.c. at edges/joints, missing nails at exterior sheathing at garage-4" o.c., missing H-25 at truss CG48C, loose roof panels at southeast are of garage and at back patio, provide truss calculations, STOPPED INSPECTION-ADDITIONAL ITEMS MSY BE ADDED.

7.23.25
Satisfactory corrections made, no additional items found.
08/04/2025 BULD - Electrical Clearance Passed Approved 8.4.25
08/04/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Approved 8.4.25
08/04/2025 COT - RSPL - Gas Pressure Test Passed Approved 8.4.25
08/15/2025 COT - RSEL - Grounding/Bonding Passed
08/15/2025 COT - RSBU - Interior Shear Bracing Passed 8.15.25
Fastener schedule verified.
09/18/2025 COT - BULD - SWG Clearance Passed 9-18-25: okay to install gas meter. SWG clearance issued.
09/24/2025 COT - RSEL - Electrical Final Passed
09/24/2025 COT - RSEL - Outdoor Lighting Passed
09/24/2025 COT - RSME - Mechanical Final Passed
09/24/2025 ENGR Engineering Final Passed Site is clear and accessible, everything is per plans.
09/24/2025 COT - RSPL - Plumbing Final Passed
09/24/2025 RSBU - Building Final Passed
09/24/2025 RSBU - Building Progress Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
241720 VALENCIA CROSSING LOT 2 PT-2025-09-11_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 2 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 2 SPECIAL INSPECTION CERTIFICATE-2024-11-08_V1.PDF DOCUMENTS VIEW