Permit: TC-MDP-1023-01592
Permit Details
Apply Date:
10/04/2023
Applicant:
John Sutton
Description:
SFR LE23004 T22-M0055
Permit Reviews
Permit Number - TC-MDP-1023-01592
Permit Status: Inspections complete
Permit Description: SFR LE23004 T22-M0055
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/04/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 10/11/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1023-01592
Permit Status: Inspections complete
Permit Description: SFR LE23004 T22-M0055
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
07/13/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
10/04/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
10/04/2023 | Post-Installed Anchor Inspection Report is required. |
10/04/2023 | Post-Tension Inspection Report is required. |
10/04/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
10/04/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-1023-01592
Permit Status: Inspections complete
Permit Description: SFR LE23004 T22-M0055
Date | Description | Comments |
---|---|---|
07/13/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01592
Permite Description: SFR LE23004 T22-M0055
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/15/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Partial Pass | Electric not finished at kitchen island, check for refrigerator being on its own circuit, bathroom door frame too narrow, plumbing not per P1 plans. Partial-pass. Ok to insulate. Check at re-inspection. |
07/15/2024 | ENGR Engineering Final | N/A | Not Ready | Evidence of pooling of the drainage from the rear yard to the front, please provide certificate or something that shows positive drainage is per plan. Nursery stakes at trees need to be removed and the proper tree stakes used. This is seen in several yards throughout the project. Clean out in front yard is too high and needs to be cut down to eliminate the trip hazard. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01592
Permit Description: SFR LE23004 T22-M0055
Total Completed Inspections - 21