Permit: TC-MDP-0925-00498
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
7458 S PYRAMID RIDGE DR
Address NEW:
7458 S PYRAMID RIDGE DR
Apply Date:
09/03/2025
Applicant:
Celina Rodriguez
Description:
Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
Permit Reviews
Permit Number - TC-MDP-0925-00498
Permit Status: Inspections
Permit Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/12/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.2 | 09/15/2025 | APPROVED |
| 09/03/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 09/11/2025 | REQUIRES RESUBMIT |
| 09/15/2025 | RESTAMP - RESIDENTIAL v.1 | 09/17/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0925-00498
Permit Status: Inspections
Permit Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
Total Outstanding Activity Conditions - 7
| Date | Name |
|---|---|
| 09/02/2025 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 09/02/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 09/02/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 09/03/2025 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 09/03/2025 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 09/03/2025 | SPECIAL INSPECTION FOR REINFORCING STEEL AND/OR PRE-STRESSING TENDONS IS REQUIRED. |
| 09/03/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0925-00498
Permit Status: Inspections
Permit Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
| Date | Description | Comments |
|---|---|---|
| 09/02/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 09/02/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00498
Permite Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2025 | COT - RSPL - Sewer | N/A | Not Ready | 9.19.2025 Not ready. |
| 09/19/2025 | COT - RSPL - Yard Water Line | N/A | Not Ready | |
| 09/23/2025 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | |
| 01/20/2026 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 1/20/26: 7458properly secure electrical whip at HVAC Condenser, disconnect at HVAC Condenser requires 36” of clearance in front, Condenser is being over Amped, cut clean outs to grade, post tension tag at hose bib required, secure plastic piping at wall abs coat all exterior plastic piping, threshold at Accessible entrance must be no more than 1/4” vertical and beveled if no more than 1/2”, light switch at garage not working, light switch at den not working, label at dryer vent must be filled out, light switch at living room not working, cover at receptacle missing in master closet, caulking required at toilets, post tension stamp at garage required, accessible route does not meet requirements, no attic access, no garage access, domestic water has not been hooked up, sewer connection has not been made, expansion tank required at water heater due to a closed loop system. Stopped inspection more items may be added. Please call future inspections under commercial permit for sales office and model home (this permit is directly correlated with the SFR) |
| 01/20/2026 | ENGR Engineering Final | N/A | Re-inspection required | Paver pathway from parking lot to sales office exceeds 2% cross slope. Paver path to sidewalk exceeds 10% running slope. Must be ADA compliant, 2% cross slope max, 5% running slope max, 8.33% max ramp slope. hand rail required where scupper passes below walkway. Transformer pad needs to be covered. Genset ungrounded. striping required. Cleanouts need to cut and covered. |
| 01/20/2026 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 1/20/26: 7458properly secure electrical whip at HVAC Condenser, disconnect at HVAC Condenser requires 36” of clearance in front, Condenser is being over Amped, cut clean outs to grade, post tension tag at hose bib required, secure plastic piping at wall abs coat all exterior plastic piping, threshold at Accessible entrance must be no more than 1/4” vertical and beveled if no more than 1/2”, light switch at garage not working, light switch at den not working, label at dryer vent must be filled out, light switch at living room not working, cover at receptacle missing in master closet, caulking required at toilets, post tension stamp at garage required, accessible route does not meet requirements, no attic access, no garage access, domestic water has not been hooked up, sewer connection has not been made, expansion tank required at water heater due to a closed loop system. Stopped inspection more items may be added. Please call future inspections under commercial permit for sales office and model home (this permit is directly correlated with the SFR) |
| 01/20/2026 | RSBU - Building Final | N/A | Re-inspection required | 1/20/26: 7458properly secure electrical whip at HVAC Condenser, disconnect at HVAC Condenser requires 36” of clearance in front, Condenser is being over Amped, cut clean outs to grade, post tension tag at hose bib required, secure plastic piping at wall abs coat all exterior plastic piping, threshold at Accessible entrance must be no more than 1/4” vertical and beveled if no more than 1/2”, light switch at garage not working, light switch at den not working, label at dryer vent must be filled out, light switch at living room not working, cover at receptacle missing in master closet, caulking required at toilets, post tension stamp at garage required, accessible route does not meet requirements, no attic access, no garage access, domestic water has not been hooked up, sewer connection has not been made, expansion tank required at water heater due to a closed loop system. Stopped inspection more items may be added. Please call future inspections under commercial permit for sales office and model home (this permit is directly correlated with the SFR) |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00498
Permit Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
Total Completed Inspections - 14