Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Address NEW:
6092 E BLACK CAVIAR PL
Apply Date:
09/26/2024
Applicant:
Helen Ormsby
Description:
Blackhawk H30M Model Plan (Model Master Plan TC-MDP-0823-01436)

Permit Reviews

Permit Number - TC-MDP-0924-01132
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan (Model Master Plan TC-MDP-0823-01436)
Start Date Submittal Complete Date Status  
09/27/2024 SITE FROM MODEL PERMIT - SUBDIVISION v.1 10/02/2024 APPROVED Review Details
10/08/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.2 10/10/2025 APPROVED Review Details
09/24/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/25/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0924-01132
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan (Model Master Plan TC-MDP-0823-01436)
Total Outstanding Activity Conditions - 1
Date Name
09/26/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/

Conditions

Permit Number - TC-MDP-0924-01132
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan (Model Master Plan TC-MDP-0823-01436)
Date Description Comments
10/01/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
10/01/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
09/26/2024 Post-Tension Inspection Report is required.
09/26/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
10/01/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
10/01/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0924-01132
Permite Description: Blackhawk H30M Model Plan (Model Master Plan TC-MDP-0823-01436)
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
06/23/2025 COT - RSPL - Rough Soil N/A Re-inspection required Plumbing not per plan. Stack needs to be topped off. 6/23/2025
06/23/2025 COT - RSPL - Sewer N/A Re-inspection required Plumbing not per plan. Stack needs to be topped off. 6/23/2025
09/08/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Partial Pass 9-8-25: partial pass replace kitchen shear wall due to too many over penetrations-structural integrity has been compromised. Shear wall to be checked at intermediates-okay to continue with construction at progress areas.
09/16/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 9.16.2025
In garage corner pop out needs foam at penetration, secure electrical line and add nail plate in garage, secure electrical lines at panel, update panel schedule and plan states conductor material is copper and not copper-clad - plan calls for 15A circuit but code E3703.5 requires 20A in garage (wire is white, should be yellow for cu clad 20A), DWV has leak in bathroom and same 3"line requires brace support, gas pressure test reading 13psi but requires 15psi, add staples at south shear wall and foam top plate as marked. Next inspector needs complete walkthrough in 1 & 2 floors. STOPPED INSPECTION, MORE ITEMS MAY BE FOUND.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-0924-01132
Permit Description: Blackhawk H30M Model Plan (Model Master Plan TC-MDP-0823-01436)
Total Completed Inspections - 21
Date Description Inspector Results Comments
06/23/2025 COT - RSPL - Yard Water Line Passed Okay to backfill. Shading is required. 6/23/2025
06/25/2025 COT - RSPL - Rough Soil Passed Okay to backfill. Shading is required. 6/25/2025
06/25/2025 COT - RSPL - Sewer Passed Okay to backfill. Shading is required. 6/25/2025
08/11/2025 COT - RSBU - Excavation/Rebar/Zoning Passed 8.11.25
Footer depths verified
Rebar verified
Pipes wrapped
Clearances verified
08/11/2025 COT - RSBU - Preslab Passed 8.11.25
Footer depths verified
Rebar verified
Pipes wrapped
Clearances verified
08/11/2025 COT - RSEL - Electrical Underground Passed 8.11.25
Footer depths verified
Rebar verified
Pipes wrapped
Clearances verified
09/04/2025 COT - RSBU - Roof Nailing Passed
09/09/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 9.9.25
Corrections made
09/16/2025 COT - RSEL - Grounding/Bonding Passed
09/18/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 9.18.2025
Corrections made to prior inspection on 9.16.2025 and walked second floor, added foam to penetrations and holes at sill plate. Shower in second floor holding water added. Staples added to main panel runs.
09/19/2025 COT - RSPL - Gas Pressure Test Passed 9-19-25: approved.
09/29/2025 COT - RSBU - Interior Shear Bracing Passed approved
10/01/2025 BULD - Electrical Clearance Passed 10/1/25: ECO TEP CLEARANCE
10/30/2025 COT - BULD - SWG Clearance Passed 10.30.2025
Clearance for Southwest Gas.
11/14/2025 COT - RSEL - Electrical Final Passed
11/14/2025 COT - RSEL - Outdoor Lighting Passed
11/14/2025 COT - RSME - Mechanical Final Passed
11/14/2025 COT - RSPL - Plumbing Final Passed
11/14/2025 ENGR Engineering Final Passed Site is complete in accordance with approved plans.
11/14/2025 RSBU - Building Final Passed
11/14/2025 RSBU - Building Progress Passed

Documents

File Name Document Type  
BHK 144 SIC-2025-10-08_V2.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
BHK 144 SIC-2024-09-26_V1.PDF DOCUMENTS VIEW
CONS-BHK 144 D1_V1.PDF DOCUMENTS VIEW