Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/04/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 9.4.2025 Front entry add flat blocks for shear wall, add another 2x4 under beam near stairs landing as marked, add web stiffener at marked locations to fill gap, missing 4ft wide exterior shear wall at landing area as marked, add 30 nails at top plate splices both sides at marked locations (NW corner area), staples over-penetrated second floor of south shear wall - check all staples, repair roof truss in north side of second floor H07 & CJ01. |
|
| 09/08/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 9-8-25: partial pass replace kitchen shear wall due to too many over penetrations-structural integrity has been compromised. Shear wall to be checked at intermediates-okay to continue with construction at progress areas. | |
| 09/09/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 9.9.25 Corrections made |