Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Complete
Type:
Model Building Permit
Apply Date:
11/16/2023
Applicant:
Daria Hopkins
Description:
SFR MERI156021 T21-M0063

Permit Reviews

Permit Number - TC-MDP-0923-01511
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063
Start Date Submittal Complete Date Status  
11/17/2023 SITE FROM MODEL PERMIT - SUBDIVISION v.1 11/22/2023 APPROVED Review Details
05/07/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 05/08/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0923-01511
Permit Status: Complete
Permit Description: SFR MERI156021 T21-M0063
Date Description Comments
11/17/2023 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
11/17/2023 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
11/17/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
11/17/2023 Post-Tension Inspection Report is required.
09/13/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
11/17/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
11/17/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0923-01511
Permit Description: SFR MERI156021 T21-M0063
Total Completed Inspections - 21
Date Description Inspector Results Comments
03/05/2024 COT - RSPL - Rough Soil Passed
03/05/2024 COT - RSPL - Sewer Passed
03/05/2024 COT - RSPL - Yard Water Line Passed
03/13/2024 COT - RSEL - Electrical Underground Passed
03/13/2024 COT - RSEL - Grounding/Bonding Passed
03/14/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
03/14/2024 COT - RSBU - Preslab Passed
04/25/2024 BULD - Electrical Clearance Passed
04/25/2024 COT - RSPL - Gas Pressure Test Passed
05/17/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
05/17/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
05/17/2024 COT - RSBU - Roof Nailing Passed
06/03/2024 COT - RSBU - Interior Shear Bracing Passed 6/3/24: passed ok to proceed
08/06/2024 COT - BULD - SWG Clearance Passed Clearance for Southwest Gas. 8/6/2024
08/29/2024 COT - RSEL - Outdoor Lighting Passed
08/29/2024 COT - RSPL - Plumbing Final Passed
08/29/2024 ENGR Engineering Final Passed Move in ready
09/04/2024 COT - RSEL - Electrical Final Passed Corrections were made. 9/4/2024
09/04/2024 COT - RSME - Mechanical Final Passed Corrections were made. 9/4/2024
09/04/2024 RSBU - Building Final Passed Corrections were made. 9/4/2024
09/04/2024 RSBU - Building Progress Passed