Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Preslab  

Permit Number - TC-MDP-0923-01511

Inspection Description - COT - RSBU - Preslab  

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/13/2024 COT - RSBU - Preslab   Re-inspection required 8/13/24: pack patio needs A.B.C properly compacted/ cleaned, per detail SD/5A holdowns require a deepen turndown of 18” ( all holdowns are under 18”), properly insulate plumbing at north west corner. PT cables at stationary end are only allowed to have 1” of exposed cable ( multiple locations with exposed cable greater than 1”).
03/14/2024 COT - RSBU - Preslab   Passed