Permit: TC-MDP-0825-00473
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
7401 S CHAMBER RIDGE DR
Address NEW:
7401 S CHAMBER RIDGE DR
Apply Date:
03/04/2026
Applicant:
Celina Rodriguez
Description:
Mirador Ridge Blossom 1383 Plan (Model master plan TC-MDP-0725-00409)
Permit Reviews
Permit Number - TC-MDP-0825-00473
Permit Status: Inspections complete
Permit Description: Mirador Ridge Blossom 1383 Plan (Model master plan TC-MDP-0725-00409)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/05/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 03/17/2026 | APPROVED |
| 07/15/2026 | SPECIAL INSPECTION REVIEW v.1 | 07/15/2026 | APPROVED |
Conditions
Permit Number - TC-MDP-0825-00473
Permit Status: Inspections complete
Permit Description: Mirador Ridge Blossom 1383 Plan (Model master plan TC-MDP-0725-00409)
| Date | Description | Comments |
|---|---|---|
| 08/27/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 08/27/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 03/06/2026 | Post-Installed Anchor Inspection Report is required. | |
| 08/27/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 08/27/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ | |
| 03/06/2026 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0825-00473
Permite Description: Mirador Ridge Blossom 1383 Plan (Model master plan TC-MDP-0725-00409)
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/01/2026 | COT - RSPL - Yard Water Line | N/A | Canceled | |
| 04/01/2026 | COT - RSPL - Sewer | N/A | Canceled | |
| 04/01/2026 | COT - RSPL - Rough Soil | N/A | Canceled | |
| 04/14/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 04/21/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 04/21/2026 Add anchor bolt at marked locations between Masa clips with arms up and edges within 12" and on shear walls, SW11 requires steel washer plates on anchor bolts every 23" o.c. in lieu of Masa clips. |
| 07/10/2026 | RSBU - Building Final | N/A | Re-inspection required | 7/10/26: clean cap at driveway must be properly secured and proper clean out cover required at driveway, No gas meter installed at time of final, PRV requires No more than 6" Above finish grade, weep screed shall not terminate closer than 4" above finish grade, properly anchor clamps at ac electrical whip, GFCI AT KITCHEN COUNTER IMPROPERLY WIRED, Water hammer arrestor label shall be cleaned and legible, Thermostat height shall be no higher than 48" AFF, Dryer vent length required at dryer box, bracket at water heater must be properly installed. Properly secure bracket B-vent at air handler, threshold at garage shall be ADA compliant. |
| 07/10/2026 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 7/10/26: clean cap at driveway must be properly secured and proper clean out cover required at driveway, No gas meter installed at time of final, PRV requires No more than 6" Above finish grade, weep screed shall not terminate closer than 4" above finish grade, properly anchor clamps at ac electrical whip, GFCI AT KITCHEN COUNTER IMPROPERLY WIRED, Water hammer arrestor label shall be cleaned and legible, Thermostat height shall be no higher than 48" AFF, Dryer vent length required at dryer box, bracket at water heater must be properly installed. Properly secure bracket B-vent at air handler, threshold at garage shall be ADA compliant. |
| 07/10/2026 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 7/10/26: clean cap at driveway must be properly secured and proper clean out cover required at driveway, No gas meter installed at time of final, PRV requires No more than 6" Above finish grade, weep screed shall not terminate closer than 4" above finish grade, properly anchor clamps at ac electrical whip, GFCI AT KITCHEN COUNTER IMPROPERLY WIRED, Water hammer arrestor label shall be cleaned and legible, Thermostat height shall be no higher than 48" AFF, Dryer vent length required at dryer box, bracket at water heater must be properly installed. Properly secure bracket B-vent at air handler, threshold at garage shall be ADA compliant. |
| 07/10/2026 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 7/10/26: clean cap at driveway must be properly secured and proper clean out cover required at driveway, No gas meter installed at time of final, PRV requires No more than 6" Above finish grade, weep screed shall not terminate closer than 4" above finish grade, properly anchor clamps at ac electrical whip, GFCI AT KITCHEN COUNTER IMPROPERLY WIRED, Water hammer arrestor label shall be cleaned and legible, Thermostat height shall be no higher than 48" AFF, Dryer vent length required at dryer box, bracket at water heater must be properly installed. Properly secure bracket B-vent at air handler, threshold at garage shall be ADA compliant. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0825-00473
Permit Description: Mirador Ridge Blossom 1383 Plan (Model master plan TC-MDP-0725-00409)
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/02/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 04/02/2026 | COT - RSPL - Sewer | Passed | ||
| 04/02/2026 | COT - RSPL - Rough Soil | Passed | ||
| 04/14/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 04/14/2026 Approved per plan and reinforcements. Okay to pour. |
|
| 04/14/2026 | COT - RSBU - Preslab | Passed | 04/14/2026 Approved per plan and reinforcements. Okay to pour. |
|
| 04/21/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 04/22/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 04/22/2026 All corrections made to prior inspection. |
|
| 05/08/2026 | BULD - Electrical Clearance | Passed | 05/08/2026 Clearance TEP ECO. |
|
| 05/08/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 05/08/2026 Added nail plates to VTR in laundry and kitchen peninsula. |
|
| 05/08/2026 | COT - RSPL - Gas Pressure Test | Passed | ||
| 05/08/2026 | COT - RSEL - Grounding/Bonding | Passed | ||
| 05/18/2026 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 07/10/2026 | COT - RSEL - Outdoor Lighting | Passed | ||
| 07/10/2026 | RSBU - Building Progress | Passed | ||
| 07/14/2026 | COT - BULD - SWG Clearance | Passed | 7-7-2026 SWG Clearance Approved. | |
| 07/14/2026 | ENGR Engineering Final | Passed | ||
| 07/14/2026 | COT - RSPL - Plumbing Final | Passed | 07/14/2026 Corrections made. |
|
| 07/14/2026 | COT - RSME - Mechanical Final | Passed | 07/14/2026 Corrections made. |
|
| 07/14/2026 | COT - RSEL - Electrical Final | Passed | 07/14/2026 Corrections made. |