Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Address:
2667 S AYALA ST
Apply Date:
07/18/2024
Applicant:
Stephanie Bebee
Description:
PV 1882 SFR

Permit Reviews

Permit Number - TC-MDP-0724-00789
Permit Status: Issued
Permit Description: PV 1882 SFR
Start Date Submittal Complete Date Status  
07/22/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 07/30/2024 REQUIRES RESUBMIT Review Details
11/15/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/18/2024 APPROVED Review Details
08/01/2024 SITE FROM MODEL PERMIT - PRODUCTION v.2 08/07/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0724-00789
Permit Status: Issued
Permit Description: PV 1882 SFR
Total Outstanding Activity Conditions - 2
Date Name
07/12/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
07/30/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-MDP-0724-00789
Permit Status: Issued
Permit Description: PV 1882 SFR
Date Description Comments
08/07/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
08/07/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
08/07/2024 Post-Tension Inspection Report is required.
07/12/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-0724-00789
Permite Description: PV 1882 SFR
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
09/06/2024 COT - RSEL - Grounding/Bonding N/A Partial Pass 9/6/24: Partial for UFER
10/07/2024 COT - RSBU - Interior Shear Bracing N/A Re-inspection required 10/7/24: Anchor bolt spacing at shear wall and perimeter not per plan, rsp4 clips missing per plan.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0724-00789
Permit Description: PV 1882 SFR
Total Completed Inspections - 8
Date Description Inspector Results Comments
08/29/2024 COT - RSPL - Backwater Valve Passed
08/30/2024 COT - RSPL - Rough Soil Passed
08/30/2024 COT - RSPL - Yard Water Line Passed
09/06/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 9/6/24: reinforcement per plan. Ok to proceed
09/06/2024 COT - RSBU - Preslab Passed 9/6/24: reinforcement per plan ok to proceed,
09/06/2024 COT - RSEL - Electrical Underground Passed 9/6/24: Electrical underground per plans
10/07/2024 COT - RSBU - Roof Nailing Passed
10/09/2024 COT - RSBU - Exterior Clips/Sheathing Passed 10/7/24: anchor bolts at shear-walls and exterior walls not per plan, properly fasten all anchor bolts, rsp4 not per plan, detail S2.1/14 missing on plans at interior bearing walls. Shot pins required 6" from edge of sill plate, shot pins required 36" o.c
10/9/24: corrections made. Ok to proceed

Documents

File Name Document Type  
PT REPORT LOT 43 -2024-11-13_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
43 PT CERT_V1.PDF DOCUMENTS VIEW
BR 43 PP FOR PERMIT_V1.PDF DOCUMENTS VIEW