Permit: TC-MDP-0723-01285
Permit Details
Apply Date:
08/23/2023
Applicant:
Andrea Flood
Description:
SFR STF40K T20-M0039 Revision Truss Calcs
Permit Reviews
Permit Number - TC-MDP-0723-01285
Permit Status: Inspections complete
Permit Description: SFR STF40K T20-M0039 Revision Truss Calcs
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/23/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 08/28/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0723-01285
Permit Status: Inspections complete
Permit Description: SFR STF40K T20-M0039 Revision Truss Calcs
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
08/23/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
08/23/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
08/23/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
08/23/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
08/28/2023 | Post-Tension Inspection Report is required. |
08/28/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0723-01285
Permit Status: Inspections complete
Permit Description: SFR STF40K T20-M0039 Revision Truss Calcs
Date | Description | Comments |
---|---|---|
07/21/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0723-01285
Permite Description: SFR STF40K T20-M0039 Revision Truss Calcs
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/21/2024 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | Missing second king stud at each end at flex room window, hallway and master bedroom entrances with 4x6 headers missing 2-2x6 studs at each end per plans, missing third lateral bracing for trusses A4, Truss A6 and A7 missing lateral bracing, missing rsp4 clip at front porch. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0723-01285
Permit Description: SFR STF40K T20-M0039 Revision Truss Calcs
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/21/2024 | COT - RSPL - Rough Soil | Passed | ||
02/27/2024 | COT - RSPL - Sewer | Passed | ||
02/28/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
02/28/2024 | COT - RSBU - Preslab | Passed | ||
02/28/2024 | COT - RSPL - Backwater Valve | Passed | ||
02/28/2024 | COT - RSEL - Electrical Underground | Passed | ||
03/18/2024 | COT - RSPL - Yard Water Line | Passed | Main water line is connected to City water supply with a meter and under street pressure. Blue tracer wire is installed. Okay to shade pipe and backfill trench. | |
03/21/2024 | COT - RSBU - Roof Nailing | Passed | ||
03/25/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 3/25/24: King studs have been added at window, hallway, and master bedroom entrances. Lateral bracing has been added for trusses A4, A6, & A7. RSP Clip has been installed at front porch. Okay to proceed with roof dry in and exterior stucco dry in. | |
04/10/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
04/10/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
04/10/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
04/19/2024 | BULD - Electrical Clearance | Passed | 4-19-24: ECO Clearance issued for 10248 E. Civano Wash Trail to TEP. | |
04/22/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
07/11/2024 | COT - BULD - SWG Clearance | Passed | SWG for meter only | |
07/22/2024 | COT - RSEL - Electrical Final | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are properly installed and fully functional. Electrical panel is properly labeled and has AFCI & GFCI Breakers installed per plan and code requirements. A/C Unit has proper breakers installed in electrical panel. Okay to issue Certificate of Occupancy after all other departments have performed their inspections. | |
07/22/2024 | COT - RSEL - Outdoor Lighting | Passed | Outdoor lighting is properly installed and functional. Light fixtures are what is specified on plans and meets city requirements. | |
07/22/2024 | COT - RSME - Mechanical Final | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are properly installed and fully functional. Electrical panel is properly labeled and has AFCI & GFCI Breakers installed per plan and code requirements. A/C Unit has proper breakers installed in electrical panel. Okay to issue Certificate of Occupancy after all other departments have performed their inspections. | |
07/22/2024 | COT - RSPL - Plumbing Final | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are properly installed and fully functional. Electrical panel is properly labeled and has AFCI & GFCI Breakers installed per plan and code requirements. A/C Unit has proper breakers installed in electrical panel. Okay to issue Certificate of Occupancy after all other departments have performed their inspections. | |
07/22/2024 | ENGR Engineering Final | Passed | Please insure that the nursery stakes are removed from the tree. Repair the swale and berm to the right of the garage. Grade looks like it will drain, did not see,your grade cert. label. |
|
07/22/2024 | RSBU - Building Final | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are properly installed and fully functional. Electrical panel is properly labeled and has AFCI & GFCI Breakers installed per plan and code requirements. A/C Unit has proper breakers installed in electrical panel. Okay to issue Certificate of Occupancy after all other departments have performed their inspections. | |
07/22/2024 | RSBU - Building Progress | Passed | Construction, mechanical, electrical, and plumbing work is complete. Mechanical, electrical, and plumbing fixtures are properly installed and fully functional. Electrical panel is properly labeled and has AFCI & GFCI Breakers installed per plan and code requirements. A/C Unit has proper breakers installed in electrical panel. Okay to issue Certificate of Occupancy after all other departments have performed their inspections. |