Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0723-01285

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/21/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing second king stud at each end at flex room window, hallway and master bedroom entrances with 4x6 headers missing 2-2x6 studs at each end per plans, missing third lateral bracing for trusses A4, Truss A6 and A7 missing lateral bracing, missing rsp4 clip at front porch.
03/25/2024 COT - RSBU - Exterior Clips/Sheathing  Passed 3/25/24: King studs have been added at window, hallway, and master bedroom entrances. Lateral bracing has been added for trusses A4, A6, & A7. RSP Clip has been installed at front porch. Okay to proceed with roof dry in and exterior stucco dry in.