Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0623-01134
Permit Details
Apply Date:
02/05/2024
Applicant:
Daria Hopkins
Description:
SFR 230.2690 T21-M0027
Permit Reviews
Permit Number - TC-MDP-0623-01134
Permit Status: Inspections complete
Permit Description: SFR 230.2690 T21-M0027
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/12/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/15/2024 | APPROVED |
02/06/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 02/13/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0623-01134
Permit Status: Inspections complete
Permit Description: SFR 230.2690 T21-M0027
Date | Description | Comments |
---|---|---|
02/06/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
02/06/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
02/13/2024 | Post-Tension Inspection Report is required. | |
06/09/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
02/13/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0623-01134
Permite Description: SFR 230.2690 T21-M0027
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/23/2024 | BULD - Electrical Clearance | N/A | Not Ready | 8/23/24: not ready |
11/15/2024 | ENGR Engineering Final | N/A | Not Ready | No access through garage, yellow caution tape across the garage door. Water puddling on the right side indication of improper drainage. Homes must be move in ready. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0623-01134
Permit Description: SFR 230.2690 T21-M0027
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/24/2024 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading is required. 6/24/2024 | |
06/24/2024 | COT - RSPL - Sewer | Passed | Okay to backfill. Shading is required. 6/24/2024 | |
06/24/2024 | COT - RSPL - Yard Water Line | Passed | Okay to backfill. Shading is required. 6/24/2024 | |
07/02/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
07/02/2024 | COT - RSBU - Preslab | Passed | ||
07/02/2024 | COT - RSEL - Electrical Underground | Passed | ||
07/02/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
07/31/2024 | COT - RSBU - Roof Nailing | Passed | ||
08/01/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
08/28/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
08/30/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Add receptacle in kitchen near stove to be within the 2'. Missing clean out in kitchen pantry. Add nail plates to electrical lines that are less than an 1 1/4". Block floor space at laundry room. Add supports for gas lines and secure in place. Move over electrical lines off gusset plates. Add foam to pex line in bathroom downstairs near can light. Leak at clean out kitchen sink. Receptacle in bedroom 2 exceeding 12'. Seal all exterior penetrations through lath. Along with tear first bedroom above header. Duct above loft area and fresh air intake are filled with water. Need to be replaced. Add strap along the bottom plates that's been over notched near refrigerant lines. Tape seams at hard ducts. Move smokie over to 6" from wall first floor outside of bedroom. 8/28/2024 8/30/24: passed |
|
09/04/2024 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. 9/4/2024 | |
09/11/2024 | COT - RSBU - Interior Shear Bracing | Passed | Passed shear wall inspection 9/11/2024 | |
10/23/2024 | COT - BULD - SWG Clearance | Passed | 10-23-24, required shut off valves and sediment trap installed.Approved for Southwest Gas connection | |
11/07/2024 | COT - RSEL - Electrical Final | Passed | 11-7-24, electrical final approved. | |
11/07/2024 | RSBU - Building Progress | Passed | ||
11/07/2024 | COT - RSME - Mechanical Final | Passed | 11-7-24, mechanical final approved. | |
11/07/2024 | COT - RSEL - Outdoor Lighting | Passed | 11-7-24, outdoor lighting final approved. | |
11/21/2024 | COT - RSPL - Plumbing Final | Passed | 11-21-24, electrical,outdoor lighting, plumbing, mechanical, and building final all approved. | |
11/21/2024 | RSBU - Building Final | Passed | 11-21-24, final approved | |
11/22/2024 | ENGR Engineering Final | Passed | CO Reday |