Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-0623-01134
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Add receptacle in kitchen near stove to be within the 2'. Missing clean out in kitchen pantry. Add nail plates to electrical lines that are less than an 1 1/4". Block floor space at laundry room. Add supports for gas lines and secure in place. Move over electrical lines off gusset plates. Add foam to pex line in bathroom downstairs near can light. Leak at clean out kitchen sink. Receptacle in bedroom 2 exceeding 12'. Seal all exterior penetrations through lath. Along with tear first bedroom above header. Duct above loft area and fresh air intake are filled with water. Need to be replaced. Add strap along the bottom plates that's been over notched near refrigerant lines. Tape seams at hard ducts. Move smokie over to 6" from wall first floor outside of bedroom. 8/28/2024 | |
08/30/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Add receptacle in kitchen near stove to be within the 2'. Missing clean out in kitchen pantry. Add nail plates to electrical lines that are less than an 1 1/4". Block floor space at laundry room. Add supports for gas lines and secure in place. Move over electrical lines off gusset plates. Add foam to pex line in bathroom downstairs near can light. Leak at clean out kitchen sink. Receptacle in bedroom 2 exceeding 12'. Seal all exterior penetrations through lath. Along with tear first bedroom above header. Duct above loft area and fresh air intake are filled with water. Need to be replaced. Add strap along the bottom plates that's been over notched near refrigerant lines. Tape seams at hard ducts. Move smokie over to 6" from wall first floor outside of bedroom. 8/28/2024 8/30/24: passed |