Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
07/25/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Missing anchor bolts throughout home. At columns and per shear wall schedules. Loose shear wall at dining area. Add stud in garage area. Add cut nails at garage entry. Add nails second floor bottom plate. (Interior). 7/25/2024
07/31/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 7/31/24: missing bottom step. Add stud to garage on north side
08/01/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed