Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Address:
466 W WYOMING ST
Address NEW:
466 W WYOMING ST
Apply Date:
05/31/2025
Applicant:
Adalberto Diaz
Description:
LUMO III New SFR (Model master plan TC-MDP-0323-00824)

Permit Reviews

Permit Number - TC-MDP-0525-00317
Permit Status: Complete
Permit Description: LUMO III New SFR (Model master plan TC-MDP-0323-00824)
Start Date Submittal Complete Date Status  
08/29/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.2 09/22/2025 APPROVED Review Details
06/02/2025 SITE FROM MODEL TEMPLATE - INFILL BUILDERS v.1 06/18/2025 REQUIRES RESUBMIT Review Details
09/22/2025 ADMINISTRATIVE v.1 09/22/2025 REQUIRES RESUBMIT Review Details
12/12/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 12/16/2025 APPROVED Review Details
10/08/2025 ADMINISTRATIVE v.3 10/08/2025 APPROVED Review Details
10/08/2025 ADMINISTRATIVE v.2 10/08/2025 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-MDP-0525-00317
Permit Status: Complete
Permit Description: LUMO III New SFR (Model master plan TC-MDP-0323-00824)
Date Description Comments
05/30/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
05/30/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
06/12/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0525-00317
Permite Description: LUMO III New SFR (Model master plan TC-MDP-0323-00824)
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
12/12/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 12-12-25: add nails at exterior 6" o.c. Along edges/splices- sheathing above exterior entryway and at marked locations, remove or properly nail any nails that are not flush at exterior sheathing, add shot pins within 6" at the ends of each plate.
12/12/2025 COT - RSPL - Sewer N/A Canceled 12-12-25: canceled by contractor.
12/23/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 12/23/2025
Add smoke detector in hallway, land the outlet and switch circuit to main panel board in dining room, add all light boxes, add exhaust fan bushing to all boxes, brace air register in hallway, move outlet receptacle within 6ft of door in main bedroom. Add fire foam to penetrations.
06/15/2026 COT - BULD - SWG Clearance N/A Not Applicable
06/15/2026 COT - RSPL - Gas Pressure Test N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0525-00317
Permit Description: LUMO III New SFR (Model master plan TC-MDP-0323-00824)
Total Completed Inspections - 19
Date Description Inspector Results Comments
10/30/2025 COT - RSPL - Rough Soil Passed Passed 10/30/25 ok to backfill
10/30/2025 COT - RSEL - Electrical Underground Passed Passed 10/30/25 ok to backfill
11/13/2025 COT - RSBU - Excavation/Rebar/Zoning Passed 11-13-25: excavation/reinforcement, preslab verified per plans-okay for concrete placement.
11/13/2025 COT - RSBU - Preslab Passed 11-13-25: excavation/reinforcement, preslab verified per plans-okay for concrete placement.
12/12/2025 COT - RSBU - Roof Nailing Passed 12-12-25: okay to dry-in roof.
12/16/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 12/16/2025
All corrections made from prior 12/12/25 inspection.
12/23/2025 COT - RSEL - Grounding/Bonding Passed 12/23/2025
Bonded UFER to main service panel with acorn.
12/23/2025 COT - RSPL - Sewer Passed 12/23/2025
Under test and holding with green tracer wire to HCS in proper trench depth - okay to backfill with shading materials.
12/23/2025 COT - RSPL - Yard Water Line Passed 12/23/2025
Under test and holding with blue tracer wire to meter in proper trench depth - okay to backfill with shading materials.
12/24/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 12/24/2025
All corrections made to yesterday's inspection.
01/05/2026 COT - RSBU - Interior Shear Bracing Passed
01/14/2026 BULD - Electrical Clearance Passed 01/14/2026
Clearance to TEP ECO.
06/15/2026 COT - RSPL - Plumbing Final Passed
06/15/2026 RSBU - Building Progress Passed
06/15/2026 RSBU - Building Final Passed
06/15/2026 COT - RSEL - Electrical Final Passed
06/15/2026 COT - RSEL - Outdoor Lighting Passed
06/15/2026 COT - RSME - Mechanical Final Passed
06/18/2026 ENGR Engineering Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL (SSRS).PDF DOCUMENTS VIEW
R91420003.25-7011-466_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
2_ 466 W WYOMING_LAYOUT1 (1)_V2.PDF DOCUMENTS VIEW