Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0523-01105
Permit Details
Apply Date:
05/30/2023
Applicant:
HSLCS Permits
Description:
Building B three-story, 24 unit, apartment building model plans
Permit Reviews
Permit Number - TC-MDP-0523-01105
Permit Status: Needs resubmittal
Permit Description: Building B three-story, 24 unit, apartment building model plans
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/05/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 07/08/2024 | REQUIRES RESUBMIT |
06/27/2023 | COMMERCIAL REVIEW - FULL v.1 | 07/24/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0523-01105
Permit Status: Needs resubmittal
Permit Description: Building B three-story, 24 unit, apartment building model plans
Total Outstanding Activity Conditions - 11
Date | Name |
---|---|
04/21/2023 | AIR BALANCING/COMMISSIONING REPORT IS REQUIRED. |
04/21/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
04/21/2023 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
04/21/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
04/21/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
07/24/2023 | WATER STERILIZATION REPORT IS REQUIRED. |
09/16/2024 | AIR BALANCING REPORT IS REQUIRED. |
09/16/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
09/16/2024 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
09/16/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
09/16/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0523-01105
Permit Status: Needs resubmittal
Permit Description: Building B three-story, 24 unit, apartment building model plans
Date | Description | Comments |
---|---|---|
05/30/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Needs Resubmittal
Permit Number: TC-MDP-0523-01105
Permite Description: Building B three-story, 24 unit, apartment building model plans
Total Outstanding Inspections - 11
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/21/2024 | COT - LCBU - Preslab | N/A | Partial Pass | 2/21/24: pre slab passed. Pending breezeway |
02/21/2024 | COT - LCEL - Grounding/Bonding | N/A | Not Ready | 2/21/24: not ready |
02/21/2024 | COT - LCEL - Electrical Underground | N/A | Partial Pass | 2/21/24: electrical underground at building slab per plan. |
02/21/2024 | COT - LCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | 2/21/24: reinforcement per plan at building slabs. Pending breezeway. |
09/05/2024 | COT - LCBU - Exterior Clips/Sheathing | N/A | Re-inspection required | Not ready. 9/5/2024 |
11/14/2024 | COT - LCEL - Electrical Above Ceiling | N/A | Re-inspection required | 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 11/14/24: properly secure NM cable on horizontal runs 48" o.c, box-fill at second floor bathroom on Nw corner overfilled, supports on sprinklers missing throughout, fire caulk all penetrations through top plate and vapor barrier, sleeves for plumbing and electrical must be sealed, nail plates required throughout for electrical and plumbing, support all DWV midway on vertical runs, support all exhaust vents midway on vertical runs, remove all electrical from gusset plates, support main water line at first floor. Over notched bearing studs must be corrected, grounding must be corrected. |
11/14/2024 | COT - LCEL - Electrical Intermediate | N/A | Re-inspection required | 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 11/14/24: properly secure NM cable on horizontal runs 48" o.c, box-fill at second floor bathroom on Nw corner overfilled, supports on sprinklers missing throughout, fire caulk all penetrations through top plate and vapor barrier, sleeves for plumbing and electrical must be sealed, nail plates required throughout for electrical and plumbing, support all DWV midway on vertical runs, support all exhaust vents midway on vertical runs, remove all electrical from gusset plates, support main water line at first floor. Over notched bearing studs must be corrected, grounding must be corrected. |
11/14/2024 | COT - LCPL - Plumbing Intermediate | N/A | Re-inspection required | 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 11/14/24: properly secure NM cable on horizontal runs 48" o.c, box-fill at second floor bathroom on Nw corner overfilled, supports on sprinklers missing throughout, fire caulk all penetrations through top plate and vapor barrier, sleeves for plumbing and electrical must be sealed, nail plates required throughout for electrical and plumbing, support all DWV midway on vertical runs, support all exhaust vents midway on vertical runs, remove all electrical from gusset plates, support main water line at first floor. Over notched bearing studs must be corrected, grounding must be corrected. |
11/14/2024 | COT - LCME - Mechanical Above Ceiling | N/A | Re-inspection required | 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 11/14/24: properly secure NM cable on horizontal runs 48" o.c, box-fill at second floor bathroom on Nw corner overfilled, supports on sprinklers missing throughout, fire caulk all penetrations through top plate and vapor barrier, sleeves for plumbing and electrical must be sealed, nail plates required throughout for electrical and plumbing, support all DWV midway on vertical runs, support all exhaust vents midway on vertical runs, remove all electrical from gusset plates, support main water line at first floor. Over notched bearing studs must be corrected, grounding must be corrected. |
11/14/2024 | COT - LCME - Mechanical Intermediate | N/A | Re-inspection required | 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 11/14/24: properly secure NM cable on horizontal runs 48" o.c, box-fill at second floor bathroom on Nw corner overfilled, supports on sprinklers missing throughout, fire caulk all penetrations through top plate and vapor barrier, sleeves for plumbing and electrical must be sealed, nail plates required throughout for electrical and plumbing, support all DWV midway on vertical runs, support all exhaust vents midway on vertical runs, remove all electrical from gusset plates, support main water line at first floor. Over notched bearing studs must be corrected, grounding must be corrected. |
11/14/2024 | COT - LCBU - Framing | N/A | Re-inspection required | 10/29/24: third flooring M.E.P above ceiling passed ok to proceed. 11/7/24: not ready for inspection 11/14/24: properly secure NM cable on horizontal runs 48" o.c, box-fill at second floor bathroom on Nw corner overfilled, supports on sprinklers missing throughout, fire caulk all penetrations through top plate and vapor barrier, sleeves for plumbing and electrical must be sealed, nail plates required throughout for electrical and plumbing, support all DWV midway on vertical runs, support all exhaust vents midway on vertical runs, remove all electrical from gusset plates, support main water line at first floor. Over notched bearing studs must be corrected, grounding must be corrected. |
Completed Inspections
Permit Status: Needs Resubmittal
Permit Number: TC-MDP-0523-01105
Permit Description: Building B three-story, 24 unit, apartment building model plans
Total Completed Inspections - 17
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2023 | COT - LCPL - Rough Soil | Passed | ||
02/20/2024 | COT - LCPL - Sewer | Passed | 2/20/24: HCS connection made. Shading required. Ok to backfill. | |
02/22/2024 | COT - LCBU - Preslab | Passed | ||
02/22/2024 | COT - LCEL - Grounding/Bonding | Passed | ||
02/22/2024 | COT - LCEL - Electrical Underground | Passed | ||
02/22/2024 | COT - LCBU - Excavation/Rebar/Zoning | Passed | ||
05/17/2024 | COT - LCPL - Yard Water Line | Passed | ||
09/05/2024 | COT - LCBU - Roof Nailing | Passed | ||
09/04/2024 | COT - LCPL - Gas Pressure Test | Passed | ||
09/09/2024 | COT - BULD - SWG Clearance | Passed | ||
09/11/2024 | COT - LCBU - Exterior Clips/Sheathing | Passed | 3rd floor approved. 9/11/2024 | |
11/14/2024 | COT - LCPL - Plumbing Above Ceiling | Passed | ||
11/14/2024 | COT - LCBU - Building Above Ceiling | Passed | ||
11/20/2024 | COT - LCEL - Electrical Above Ceiling | Passed | ||
11/20/2024 | COT - LCPL - Plumbing Intermediate | Passed | ||
11/20/2024 | COT - LCME - Mechanical Above Ceiling | Passed | ||
11/20/2024 | COT - LCME - Mechanical Intermediate | Passed |
Scheduled Inspections
Scheduled Inspections - TC-MDP-0523-01105
Status: Needs Resubmittal
Description: Building B three-story, 24 unit, apartment building model plans
Scheduled Date | Description | Entered By | Entered Date |
---|---|---|---|
11/22/2024 | COT - LCBU - Framing | Scheduled | |
11/20/2024 | COT - LCEL - Electrical Intermediate | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.