Permit: TC-MDP-0426-00223
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
10034 E LEBARON
Address NEW:
10034 E LEBARON
Apply Date:
04/14/2026
Applicant:
Celina Rodriguez
Description:
Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
Permit Reviews
Permit Number - TC-MDP-0426-00223
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/16/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 04/27/2026 | APPROVED |
| 08/28/2026 | SPECIAL INSPECTION REVIEW v.1 | 09/02/2026 | APPROVED |
Conditions
Permit Number - TC-MDP-0426-00223
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
| Date | Description | Comments |
|---|---|---|
| 04/09/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. | |
| 04/30/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 04/09/2026 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 04/23/2026 | Post-Installed Anchor Inspection Report is required. | |
| 04/09/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 04/23/2026 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. | |
| 04/09/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0426-00223
Permite Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
Total Outstanding Inspections - 7
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/01/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | |
| 06/01/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 1. Garage entry door into living space is missing 1 king stud. 2. Nail in diagonal bracings properly per detail 301. 3. SW11 Shear walls are missing some washers 4. Provide truss calcs. |
| 08/24/2026 | ENGR Engineering Final | N/A | Partial Pass | Site is complete in accordance with approved plans. Outstanding conditions prevent full pass of Final. |
| 08/24/2026 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 8-24-26 clean out caps are required to be glued to prevent them from coming off completely* condensing unit requires to be leveled properly* 3 inches of clearance around condensing pad is required* post tension tag required at hose bib* 20 minute rated tag at fire door at garage needs to be visible* threshold at garage entry to home requires ADA accessibility* electrical at great room for fans and lights are all tied in together as well as once you turn that three-way switch off for the lights the fan turns off as well and the half hot receptacle located under window in great room at Northwest corner turns on simultaneously, not wired to specs.* two receptacles located at great room on North wall closest to front door are without power* flex duct in attic crawlspace area coming off of FAU has tear in it needs repair. |
| 08/24/2026 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 8-24-26 clean out caps are required to be glued to prevent them from coming off completely* condensing unit requires to be leveled properly* 3 inches of clearance around condensing pad is required* post tension tag required at hose bib* 20 minute rated tag at fire door at garage needs to be visible* threshold at garage entry to home requires ADA accessibility* electrical at great room for fans and lights are all tied in together as well as once you turn that three-way switch off for the lights the fan turns off as well and the half hot receptacle located under window in great room at Northwest corner turns on simultaneously, not wired to specs.* two receptacles located at great room on North wall closest to front door are without power* flex duct in attic crawlspace area coming off of FAU has tear in it needs repair. |
| 08/24/2026 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 8-24-26 clean out caps are required to be glued to prevent them from coming off completely* condensing unit requires to be leveled properly* 3 inches of clearance around condensing pad is required* post tension tag required at hose bib* 20 minute rated tag at fire door at garage needs to be visible* threshold at garage entry to home requires ADA accessibility* electrical at great room for fans and lights are all tied in together as well as once you turn that three-way switch off for the lights the fan turns off as well and the half hot receptacle located under window in great room at Northwest corner turns on simultaneously, not wired to specs.* two receptacles located at great room on North wall closest to front door are without power* flex duct in attic crawlspace area coming off of FAU has tear in it needs repair. |
| 08/24/2026 | RSBU - Building Final | N/A | Re-inspection required | 8-24-26 clean out caps are required to be glued to prevent them from coming off completely* condensing unit requires to be leveled properly* 3 inches of clearance around condensing pad is required* post tension tag required at hose bib* 20 minute rated tag at fire door at garage needs to be visible* threshold at garage entry to home requires ADA accessibility* electrical at great room for fans and lights are all tied in together as well as once you turn that three-way switch off for the lights the fan turns off as well and the half hot receptacle located under window in great room at Northwest corner turns on simultaneously, not wired to specs.* two receptacles located at great room on North wall closest to front door are without power* flex duct in attic crawlspace area coming off of FAU has tear in it needs repair. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0426-00223
Permit Description: Mirador Ridge Blossom 1465 Plan (Model master plan TC-MDP-0725-00408)
Total Completed Inspections - 18
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/12/2026 | COT - RSPL - Yard Water Line | Passed | 5.12.26 Approved |
|
| 05/12/2026 | COT - RSPL - Rough Soil | Passed | 5.12.26 Approved |
|
| 05/12/2026 | COT - RSPL - Sewer | Passed | 5.12.26 Approved |
|
| 05/18/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 5.18.26 Approved |
|
| 05/18/2026 | COT - RSBU - Preslab | Passed | ||
| 05/18/2026 | COT - RSEL - Electrical Underground | Passed | ||
| 06/04/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 06/08/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 06/12/2026 | BULD - Electrical Clearance | Passed | ||
| 06/12/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 07/02/2026 | COT - RSBU - Interior Shear Bracing | Passed | 07/02/2026 Corrections made to drywall screw spacing. |
|
| 08/14/2026 | COT - BULD - SWG Clearance | Passed | 8-14-26 SWG Clearance approved | |
| 08/19/2026 | COT - RSPL - Gas Pressure Test | Passed | 8-19-26 gas pressure test approved pass | |
| 08/24/2026 | COT - RSEL - Outdoor Lighting | Passed | ||
| 08/24/2026 | RSBU - Building Progress | Passed | ||
| 08/27/2026 | COT - RSEL - Electrical Final | Passed | 8-27-26 All items are corrected electrical final approved | |
| 08/27/2026 | COT - RSME - Mechanical Final | Passed | 8-27-26 All items are corrected mechanical final approved. | |
| 08/27/2026 | COT - RSPL - Plumbing Final | Passed | 8-27-26 all items were corrected plumbing final approved |