Permit Details

Status:
Complete
Type:
Model Building Permit
Apply Date:
04/25/2024
Applicant:
Daria Hopkins
Description:
SFR 230.2380 T21-M0028

Permit Reviews

Permit Number - TC-MDP-0424-00510
Permit Status: Complete
Permit Description: SFR 230.2380 T21-M0028
Start Date Submittal Complete Date Status  
04/29/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 05/06/2024 APPROVED Review Details
12/13/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 12/13/2024 APPROVED Review Details
08/23/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/23/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0424-00510
Permit Status: Complete
Permit Description: SFR 230.2380 T21-M0028
Date Description Comments
05/01/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
05/01/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
05/01/2024 Post-Tension Inspection Report is required.
04/25/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
04/25/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
05/01/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0424-00510
Permite Description: SFR 230.2380 T21-M0028
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
07/18/2024 COT - RSBU - Preslab N/A Re-inspection required 7/18/24: missing hold downs
07/18/2024 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 7/18/24: missing hold downs
08/02/2024 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required Missing 4x8 header at back patio along with straps. Missing 2x4 cripple studs at dinning room window along with blocking in between floor trusses on both ends. Garage beam calls for x3 2x6 trimmers. Missing cs16 strap at garage area. Missing bottom and top tread at stairs. Missing cs16 strap at transition above powder room. Tighten down loose bolts. Provide anchor bolts at marked areas. Add rsp clips to header at dinning area. Add more nails to exterior perimeter at marked areas. Missing h25 at girder truss. 8/2/2024
09/04/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Receptacle in bedroom exceeding 12’. Missing receptacle in bathroom for double vanity. Insulate pex lines in great room and master bath areas. DWV throughout 2nd floor. Missing tread and stairway. Add nail plate at pantry. 9/4/2024

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0424-00510
Permit Description: SFR 230.2380 T21-M0028
Total Completed Inspections - 21
Date Description Inspector Results Comments
07/09/2024 COT - RSPL - Yard Water Line Passed Okay to backfill. Shading required. 7/9/2024
07/09/2024 COT - RSPL - Rough Soil Passed Okay to backfill. Shading required. 7/9/2024
07/11/2024 COT - RSPL - Sewer Passed Okay to backfill. Shading required. 7/11/2024
07/18/2024 COT - RSEL - Electrical Underground Passed
07/18/2024 COT - RSEL - Grounding/Bonding Passed
07/22/2024 COT - RSBU - Preslab Passed Approved for concrete placement. 7/22/2024
07/22/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Approved for concrete placement. 7/22/2024
08/06/2024 COT - RSBU - Exterior Clips/Sheathing Passed Corrections were made. 8/6/2024
08/06/2024 COT - RSBU - Roof Nailing Passed Corrections were made. 8/6/2024
09/04/2024 BULD - Electrical Clearance Passed Clearance for TEP ECO. 9/4/2024
09/04/2024 COT - RSPL - Gas Pressure Test Passed
09/06/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Approved. Corrections were made. 9/6/2024
09/26/2024 COT - RSBU - Interior Shear Bracing Passed Pass 9/26/2024
11/05/2024 COT - BULD - SWG Clearance Passed 11-5-24, approved for Southwest Gas connection.
11/19/2024 COT - RSEL - Outdoor Lighting Passed 11-19-24, approved.
11/19/2024 ENGR Engineering Final Passed CO Ready

Construction materials and staging parts in frt. yard
11/26/2024 COT - RSEL - Electrical Final Passed 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved.
11/26/2024 COT - RSME - Mechanical Final Passed 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved.
11/26/2024 COT - RSPL - Plumbing Final Passed 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved.
11/26/2024 RSBU - Building Final Passed 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved.
11/26/2024 RSBU - Building Progress Passed 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved.

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
148990 PT LOT 41 COMPLETE-2024-08-22_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 41 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 41 SPECIAL INSPECTION CERTIFICATE-2024-04-26_V1.PDF DOCUMENTS VIEW