Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0424-00510
Permit Details
Apply Date:
04/25/2024
Applicant:
Daria Hopkins
Description:
SFR 230.2380 T21-M0028
Permit Reviews
Permit Number - TC-MDP-0424-00510
Permit Status: Complete
Permit Description: SFR 230.2380 T21-M0028
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/29/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 05/06/2024 | APPROVED |
12/13/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 12/13/2024 | APPROVED |
08/23/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/23/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0424-00510
Permit Status: Complete
Permit Description: SFR 230.2380 T21-M0028
Date | Description | Comments |
---|---|---|
05/01/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
05/01/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
05/01/2024 | Post-Tension Inspection Report is required. | |
04/25/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
04/25/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
05/01/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0424-00510
Permite Description: SFR 230.2380 T21-M0028
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/18/2024 | COT - RSBU - Preslab | N/A | Re-inspection required | 7/18/24: missing hold downs |
07/18/2024 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 7/18/24: missing hold downs |
08/02/2024 | COT - RSBU - Exterior Clips/Sheathing | N/A | Re-inspection required | Missing 4x8 header at back patio along with straps. Missing 2x4 cripple studs at dinning room window along with blocking in between floor trusses on both ends. Garage beam calls for x3 2x6 trimmers. Missing cs16 strap at garage area. Missing bottom and top tread at stairs. Missing cs16 strap at transition above powder room. Tighten down loose bolts. Provide anchor bolts at marked areas. Add rsp clips to header at dinning area. Add more nails to exterior perimeter at marked areas. Missing h25 at girder truss. 8/2/2024 |
09/04/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | Receptacle in bedroom exceeding 12’. Missing receptacle in bathroom for double vanity. Insulate pex lines in great room and master bath areas. DWV throughout 2nd floor. Missing tread and stairway. Add nail plate at pantry. 9/4/2024 |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0424-00510
Permit Description: SFR 230.2380 T21-M0028
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/09/2024 | COT - RSPL - Yard Water Line | Passed | Okay to backfill. Shading required. 7/9/2024 | |
07/09/2024 | COT - RSPL - Rough Soil | Passed | Okay to backfill. Shading required. 7/9/2024 | |
07/11/2024 | COT - RSPL - Sewer | Passed | Okay to backfill. Shading required. 7/11/2024 | |
07/18/2024 | COT - RSEL - Electrical Underground | Passed | ||
07/18/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
07/22/2024 | COT - RSBU - Preslab | Passed | Approved for concrete placement. 7/22/2024 | |
07/22/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Approved for concrete placement. 7/22/2024 | |
08/06/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Corrections were made. 8/6/2024 | |
08/06/2024 | COT - RSBU - Roof Nailing | Passed | Corrections were made. 8/6/2024 | |
09/04/2024 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. 9/4/2024 | |
09/04/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
09/06/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Approved. Corrections were made. 9/6/2024 | |
09/26/2024 | COT - RSBU - Interior Shear Bracing | Passed | Pass 9/26/2024 | |
11/05/2024 | COT - BULD - SWG Clearance | Passed | 11-5-24, approved for Southwest Gas connection. | |
11/19/2024 | COT - RSEL - Outdoor Lighting | Passed | 11-19-24, approved. | |
11/19/2024 | ENGR Engineering Final | Passed | CO Ready Construction materials and staging parts in frt. yard |
|
11/26/2024 | COT - RSEL - Electrical Final | Passed | 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved. | |
11/26/2024 | COT - RSME - Mechanical Final | Passed | 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved. | |
11/26/2024 | COT - RSPL - Plumbing Final | Passed | 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved. | |
11/26/2024 | RSBU - Building Final | Passed | 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved. | |
11/26/2024 | RSBU - Building Progress | Passed | 11-26-24, plumbing, mechanical, outdoor lighting, electrical, and building final approved. |