Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof NailingĀ
| Date |
Description |
Inspector |
Results |
Comments |
| 08/02/2024 |
COT - RSBU - Roof NailingĀ |
|
Re-inspection required |
Missing 4x8 header at back patio along with straps. Missing 2x4 cripple studs at dinning room window along with blocking in between floor trusses on both ends. Garage beam calls for x3 2x6 trimmers. Missing cs16 strap at garage area. Missing bottom and top tread at stairs. Missing cs16 strap at transition above powder room. Tighten down loose bolts. Provide anchor bolts at marked areas. Add rsp clips to header at dinning area. Add more nails to exterior perimeter at marked areas. Missing h25 at girder truss. 8/2/2024 |
| 08/06/2024 |
COT - RSBU - Roof NailingĀ |
|
Passed |
Corrections were made. 8/6/2024 |