Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0424-00510

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/02/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing 4x8 header at back patio along with straps. Missing 2x4 cripple studs at dinning room window along with blocking in between floor trusses on both ends. Garage beam calls for x3 2x6 trimmers. Missing cs16 strap at garage area. Missing bottom and top tread at stairs. Missing cs16 strap at transition above powder room. Tighten down loose bolts. Provide anchor bolts at marked areas. Add rsp clips to header at dinning area. Add more nails to exterior perimeter at marked areas. Missing h25 at girder truss. 8/2/2024
08/06/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Corrections were made. 8/6/2024