Permit: TC-MDP-0424-00503
Permit Details
Apply Date:
04/19/2024
Applicant:
Celina Rodriguez
Description:
SFR BT2013-140 T22-M0036
Permit Reviews
Permit Number - TC-MDP-0424-00503
Permit Status: Inspections complete
Permit Description: SFR BT2013-140 T22-M0036
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/19/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 05/01/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0424-00503
Permit Status: Inspections complete
Permit Description: SFR BT2013-140 T22-M0036
Total Outstanding Activity Conditions - 5
Date | Name |
---|---|
04/17/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
04/19/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
04/19/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
04/19/2024 | Post-Tension Inspection Report is required. |
04/19/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-0424-00503
Permit Status: Inspections complete
Permit Description: SFR BT2013-140 T22-M0036
Date | Description | Comments |
---|---|---|
04/17/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0424-00503
Permite Description: SFR BT2013-140 T22-M0036
Total Outstanding Inspections - 4
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/04/2024 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 10/4/24: Pressure relief valve must terminate 6" above grade, A/C condenser must have a 3" clearance from grade, GFCI required at laundry room, please leave approved plan set for final inspection, post tension tag required at hose bib, smoke alarms must be interconnected, |
10/04/2024 | COT - RSME - Mechanical Final | N/A | Re-inspection required | 10/4/24: Pressure relief valve must terminate 6" above grade, A/C condenser must have a 3" clearance from grade, GFCI required at laundry room, please leave approved plan set for final inspection, post tension tag required at hose bib, smoke alarms must be interconnected, |
10/04/2024 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 10/4/24: Pressure relief valve must terminate 6" above grade, A/C condenser must have a 3" clearance from grade, GFCI required at laundry room, please leave approved plan set for final inspection, post tension tag required at hose bib, smoke alarms must be interconnected, |
10/04/2024 | RSBU - Building Final | N/A | Re-inspection required | 10/4/24: Pressure relief valve must terminate 6" above grade, A/C condenser must have a 3" clearance from grade, GFCI required at laundry room, please leave approved plan set for final inspection, post tension tag required at hose bib, smoke alarms must be interconnected, |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-0424-00503
Permit Description: SFR BT2013-140 T22-M0036
Total Completed Inspections - 21
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/09/2024 | COT - RSPL - Yard Water Line | Passed | ||
05/09/2024 | COT - RSPL - Sewer | Passed | ||
05/09/2024 | COT - RSPL - Rough Soil | Passed | ||
05/15/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
05/15/2024 | COT - RSEL - Electrical Underground | Passed | ||
05/16/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
05/16/2024 | COT - RSBU - Preslab | Passed | ||
06/06/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | ||
06/06/2024 | COT - RSBU - Roof Nailing | Passed | ||
07/05/2024 | COT - RSPL - Gas Pressure Test | Passed | Gas line under air pressure of 15# and holding with no leaks. | |
07/10/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 7/10/24: Ductwork is now complete and smoke detector in bedroom #2 has been relocated to 6 feet away from register. Okay to proceed with insulation and drywall installation. | |
07/26/2024 | COT - RSBU - Interior Shear Bracing | Passed | Drywall for interior shear walls is properly secured to studs per plan requirements. Okay to proceed with drywall tape, texture, and paint. | |
08/01/2024 | BULD - Electrical Clearance | Passed | Clearance for TEP ECO. 8/1/2024 | |
09/16/2024 | COT - BULD - SWG Clearance | Passed | Passes electrical clearance ECO 9/16/2024 | |
10/04/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
10/04/2024 | ENGR Engineering Final | Passed | CO Ready | |
10/04/2024 | RSBU - Building Progress | Passed | ||
10/09/2024 | COT - RSEL - Electrical Final | Passed | 10/9/24: All items noted above have been corrected. Construction is complete. Okay to issue Certificate of Occupancy. | |
10/09/2024 | COT - RSME - Mechanical Final | Passed | 10/9/24: All items noted above have been corrected. Construction is complete. Okay to issue Certificate of Occupancy. | |
10/09/2024 | COT - RSPL - Plumbing Final | Passed | 10/9/24: All items noted above have been corrected. Construction is complete. Okay to issue Certificate of Occupancy. | |
10/09/2024 | RSBU - Building Final | Passed | 10/9/24: All items noted above have been corrected. Construction is complete. Okay to issue Certificate of Occupancy. |