Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0424-00503
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 5/4/24: shear wall missing nailing at entry. Add anchor bolts where masa clips have excessive legs up (more than 1 leg up for every three in a row) missing nailing at rsp clip on east side of home. All bearing points for girder and trusts must have clip front and back of home. Shim trust. Stopped inspection | ||
06/06/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |