Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0424-00503

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 5/4/24: shear wall missing nailing at entry. Add anchor bolts where masa clips have excessive legs up (more than 1 leg up for every three in a row) missing nailing at rsp clip on east side of home. All bearing points for girder and trusts must have clip front and back of home. Shim trust. Stopped inspection
06/06/2024 COT - RSBU - Exterior Clips/Sheathing  Passed