Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
Permit Number - TC-MDP-0424-00503
Inspection Description - COT - RSME - Mechanical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/04/2024 | COT - RSME - Mechanical Final | Re-inspection required | 10/4/24: Pressure relief valve must terminate 6" above grade, A/C condenser must have a 3" clearance from grade, GFCI required at laundry room, please leave approved plan set for final inspection, post tension tag required at hose bib, smoke alarms must be interconnected, | |
10/09/2024 | COT - RSME - Mechanical Final | Passed | 10/9/24: All items noted above have been corrected. Construction is complete. Okay to issue Certificate of Occupancy. |