Permit: TC-MDP-0424-00386
Permit Details
Status:
Complete
Type:
Model Building Permit
Address:
6037 E CAMPOLINA TR
Address NEW:
6037 E CAMPOLINA TR
Apply Date:
04/03/2024
Applicant:
Brian Jones
Description:
Blackhawk T933 - Beech
Permit Reviews
Permit Number - TC-MDP-0424-00386
Permit Status: Complete
Permit Description: Blackhawk T933 - Beech
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/12/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.2 | 04/18/2024 | APPROVED |
| 04/18/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 04/21/2025 | APPROVED |
| 04/18/2024 | RESTAMP - RESIDENTIAL v.1 | 04/18/2024 | APPROVED |
| 05/30/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 05/30/2025 | REQUIRES RESUBMIT |
| 08/01/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 08/01/2025 | APPROVED |
| 04/04/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 04/09/2024 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-MDP-0424-00386
Permit Status: Complete
Permit Description: Blackhawk T933 - Beech
| Date | Description | Comments |
|---|---|---|
| 04/01/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 04/05/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 04/05/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 04/01/2024 | Post-Tension Inspection Report is required. | |
| 04/01/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 04/01/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
| 04/05/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0424-00386
Permite Description: Blackhawk T933 - Beech
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 6/21/24: Anchor bolts missing throughout 12" from edge of sill plate, anchor bolt spacing at shear walls not per plan, A35 clips required at cross bracing at gable end, truss bracing missing per truss clacs. |
| 06/21/2024 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 6/21/24: Anchor bolts missing throughout 12" from edge of sill plate, anchor bolt spacing at shear walls not per plan, A35 clips required at cross bracing at gable end, truss bracing missing per truss clacs. Roofing not checked no ladder provided. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0424-00386
Permit Description: Blackhawk T933 - Beech
Total Completed Inspections - 21