Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0224-00199
Permit Details
Apply Date:
02/08/2024
Applicant:
Joshua Swinney
Description:
Black Mountain model SFR Escalara
Permit Reviews
Permit Number - TC-MDP-0224-00199
Permit Status: Issued
Permit Description: Black Mountain model SFR Escalara
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
04/25/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 04/30/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0224-00199
Permit Status: Issued
Permit Description: Black Mountain model SFR Escalara
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
01/20/2023 | Post-Tension Inspection Report is required. |
02/08/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
04/26/2024 | Post-Installed Anchor Inspection Report is required. |
04/26/2024 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0224-00199
Permit Status: Issued
Permit Description: Black Mountain model SFR Escalara
Date | Description | Comments |
---|---|---|
04/30/2024 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
02/08/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
01/20/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-MDP-0224-00199
Permite Description: Black Mountain model SFR Escalara
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/06/2024 | COT - RSBU - Exterior Clips/Sheathing | N/A | Not Applicable | 8/6/24: no plans |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-0224-00199
Permit Description: Black Mountain model SFR Escalara
Total Completed Inspections - 11
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/07/2024 | COT - RSPL - Rough Soil | Passed | ||
06/07/2024 | COT - RSPL - Yard Water Line | Passed | ||
06/17/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is evenly spaced, rebar reinforcement is properly installed per plan, Ufer ground is installed, underground plumbing is properly wrapped for protection, and underground electrical for kitchen island is installed. Okay to proceed with concrete pour. | |
06/17/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is evenly spaced, rebar reinforcement is properly installed per plan, Ufer ground is installed, underground plumbing is properly wrapped for protection, and underground electrical for kitchen island is installed. Okay to proceed with concrete pour. | |
06/17/2024 | COT - RSEL - Electrical Underground | Passed | Concrete forms are set, post tension cabling is evenly spaced, rebar reinforcement is properly installed per plan, Ufer ground is installed, underground plumbing is properly wrapped for protection, and underground electrical for kitchen island is installed. Okay to proceed with concrete pour. | |
06/17/2024 | COT - RSEL - Grounding/Bonding | Passed | Concrete forms are set, post tension cabling is evenly spaced, rebar reinforcement is properly installed per plan, Ufer ground is installed, underground plumbing is properly wrapped for protection, and underground electrical for kitchen island is installed. Okay to proceed with concrete pour. | |
08/07/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Exterior and interior walls are properly secured to concrete floor with j-bolts, titan bolts, shot pins, or masa clips. Shear wall plywood sheathing is properly installed and secured to studs with nails per plan requirements. Okay to proceed with rough-in of mechanical, electrical, and plumbing work. | |
08/07/2024 | COT - RSBU - Roof Nailing | Passed | 8/7/24: Simpson 2x4 Hangers have been installed on GLB. 2X6 studs have been installed in pantry wall for 2nd floor landing support. Shear wall at pantry sheathing has been properly secured to studs. CS16 straps have been installed on south shear wall. Bottom plate of interior and exterior walls of 2nd floor have been nailed to wood floor decking between every stud at least three or four nails in plate. Okay to proceed with rough-in of mechanical, electrical, and plumbing. | |
09/20/2024 | COT - RSPL - Sewer | Passed | ||
10/14/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
11/12/2024 | COT - RSBU - Interior Shear Bracing | Passed | 11-12-24, interior shear wall approved. Okay to tape and texture drywall. |