Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0224-00199
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/01/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing hangers per plan in garage at GLB. Trimmers in pantry call for x2 2x6's. Loose shear wall at pantry marked areas. Provide titans at marked locations. Missing cs16 straps at shear wall south of home. Nailing pattern not per schedule at interior bottom plate. 8/1/2024 | |
08/06/2024 | COT - RSBU - Exterior Clips/Sheathing | Not Applicable | 8/6/24: no plans | |
08/07/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Exterior and interior walls are properly secured to concrete floor with j-bolts, titan bolts, shot pins, or masa clips. Shear wall plywood sheathing is properly installed and secured to studs with nails per plan requirements. Okay to proceed with rough-in of mechanical, electrical, and plumbing work. |