Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0224-00199
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/01/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing hangers per plan in garage at GLB. Trimmers in pantry call for x2 2x6's. Loose shear wall at pantry marked areas. Provide titans at marked locations. Missing cs16 straps at shear wall south of home. Nailing pattern not per schedule at interior bottom plate. 8/1/2024 | |
08/07/2024 | COT - RSBU - Roof Nailing | Passed | 8/7/24: Simpson 2x4 Hangers have been installed on GLB. 2X6 studs have been installed in pantry wall for 2nd floor landing support. Shear wall at pantry sheathing has been properly secured to studs. CS16 straps have been installed on south shear wall. Bottom plate of interior and exterior walls of 2nd floor have been nailed to wood floor decking between every stud at least three or four nails in plate. Okay to proceed with rough-in of mechanical, electrical, and plumbing. |