Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
01/18/2024
Applicant:
Dana Petty
Description:
SFR MER1502320 T21-M0070

Permit Reviews

Permit Number - TC-MDP-0223-00605
Permit Status: Issued
Permit Description: SFR MER1502320 T21-M0070
Start Date Submittal Complete Date Status  
01/19/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 01/25/2024 APPROVED Review Details
09/26/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/27/2024 APPROVED Review Details
06/20/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 06/21/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0223-00605
Permit Status: Issued
Permit Description: SFR MER1502320 T21-M0070
Date Description Comments
01/19/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
01/19/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
01/19/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
01/23/2024 Post-Tension Inspection Report is required.
01/19/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
01/19/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
01/23/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-0223-00605
Permit Description: SFR MER1502320 T21-M0070
Total Completed Inspections - 21
Date Description Inspector Results Comments
04/23/2024 COT - RSPL - Sewer Passed
04/23/2024 COT - RSPL - Rough Soil Passed
04/23/2024 COT - RSPL - Yard Water Line Passed
05/06/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Concrete forms are set, masa clips are spaced properly, shear wall clips are in place per plans, rebar reinforcement is in place per plans, post tension cabling is installed and properly spaced per plans, plumbing pipes are properly wrapped with foam for protection, underground electrical for kitchen island is installed, and Ufer ground is installed on right side of garage. Okay to pour concrete for footings and slab on grade.
05/06/2024 COT - RSBU - Preslab Passed Concrete forms are set, masa clips are spaced properly, shear wall clips are in place per plans, rebar reinforcement is in place per plans, post tension cabling is installed and properly spaced per plans, plumbing pipes are properly wrapped with foam for protection, underground electrical for kitchen island is installed, and Ufer ground is installed on right side of garage. Okay to pour concrete for footings and slab on grade.
05/06/2024 COT - RSEL - Electrical Underground Passed Concrete forms are set, masa clips are spaced properly, shear wall clips are in place per plans, rebar reinforcement is in place per plans, post tension cabling is installed and properly spaced per plans, plumbing pipes are properly wrapped with foam for protection, underground electrical for kitchen island is installed, and Ufer ground is installed on right side of garage. Okay to pour concrete for footings and slab on grade.
05/06/2024 COT - RSEL - Grounding/Bonding Passed Concrete forms are set, masa clips are spaced properly, shear wall clips are in place per plans, rebar reinforcement is in place per plans, post tension cabling is installed and properly spaced per plans, plumbing pipes are properly wrapped with foam for protection, underground electrical for kitchen island is installed, and Ufer ground is installed on right side of garage. Okay to pour concrete for footings and slab on grade.
05/22/2024 COT - RSBU - Exterior Clips/Sheathing Passed Exterior and interior walls are properly secured to concrete floor with cut nails, bolts or a/b bolts. Shear wall hold downs are properly nailed to studs in walls per plan and code. Plywood sheathing on shear walls is properly nailed per plans. Straps are installed and secured to headers of all large openings. Okay to proceed.
05/22/2024 COT - RSBU - Roof Nailing Passed Roof trusses are properly secured to top plate with h2.5 clips. Plywood roof sheathing is properly nailed to trusses. Okay to proceed.
06/14/2024 BULD - Electrical Clearance Passed Electrical panel is properly secured to wall and connected to the Ufer ground. Temporary breakers and outlet is installed. Issuing a ECO Clearance to TEP for 10547 e rosy marble dr.
06/14/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall.
06/14/2024 COT - RSPL - Gas Pressure Test Passed Gas line is holding 15# of compressed air. Okay to proceed.
07/08/2024 COT - RSBU - Interior Shear Bracing Passed
09/05/2024 COT - BULD - SWG Clearance Passed
09/13/2024 COT - RSEL - Electrical Final Passed
09/13/2024 COT - RSEL - Outdoor Lighting Passed
09/13/2024 COT - RSME - Mechanical Final Passed
09/13/2024 COT - RSPL - Plumbing Final Passed
09/12/2024 ENGR Engineering Final Passed
09/13/2024 RSBU - Building Final Passed
09/13/2024 RSBU - Building Progress Passed

Documents

File Name Document Type  
TRUSS DESIGN DRAWINGS_V1.PDF DOCUMENTS VIEW
147402 PT LOT 75 COMPLETE-2024-06-18_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 75 APPLICATION_V1.PDF DOCUMENTS VIEW
LOT 75 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 75 SPECIAL INSPECTION CERTIFICATE-2024-01-18_V1.PDF DOCUMENTS VIEW