Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0223-00522
Permit Details
Apply Date:
01/05/2024
Applicant:
Dana Petty
Description:
SFR MER2403280 T21-M0074
Permit Reviews
Permit Number - TC-MDP-0223-00522
Permit Status: Issued
Permit Description: SFR MER2403280 T21-M0074
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/08/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/11/2024 | APPROVED |
07/29/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/02/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0223-00522
Permit Status: Issued
Permit Description: SFR MER2403280 T21-M0074
Date | Description | Comments |
---|---|---|
01/08/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
01/08/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
01/08/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
01/11/2024 | Post-Tension Inspection Report is required. | |
01/08/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
01/08/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
08/01/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
01/11/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Issued
Permit Number: TC-MDP-0223-00522
Permit Description: SFR MER2403280 T21-M0074
Total Completed Inspections - 14
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2024 | COT - RSPL - Backwater Valve | Passed | Underground plumbing & backwater valve are connected to main sewer line. Entire system is under a water test with no leaks. Okay to shade pipe and backfill trenches. | |
06/10/2024 | COT - RSPL - Yard Water Line | Passed | Main water supply line is installed from meter to house with blue tracer wire attached to pipe. System is under street pressure with no leaks. Okay to shade pipe and backfill trench. | |
06/10/2024 | COT - RSPL - Rough Soil | Passed | Underground plumbing & backwater valve are connected to main sewer line. Entire system is under a water test with no leaks. Okay to shade pipe and backfill trenches. | |
06/10/2024 | COT - RSPL - Sewer | Passed | Underground plumbing & backwater valve are connected to main sewer line. Entire system is under a water test with no leaks. Okay to shade pipe and backfill trenches. | |
06/18/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
06/18/2024 | COT - RSBU - Preslab | Passed | ||
06/18/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
06/18/2024 | COT - RSEL - Electrical Underground | Passed | ||
07/22/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Exterior and interior plywood shear walls are properly installed, bolted, and nailed per the plans. All masa clips are properly nailed to bottom plate, all shear wall hold downs are properly nailed to wall studs, and titan bolts are installed were joints in bottom plate happened. Okay to proceed with rough-in of mechanical, electrical, and plumbing. | |
07/22/2024 | COT - RSBU - Roof Nailing | Passed | Roof trusses are properly installed and secured to the top plate with nails and H2.5 clips. Roof sheathing is properly secured to the roof trusses with nails and staples. | |
08/22/2024 | BULD - Electrical Clearance | Passed | TEP eco | |
08/22/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
08/23/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 8/23/24: Studs have been added under girder trusses in bedroom #4. Box for ceiling light/fan installed and wire installed inside box. Okay to proceed with installation of insulation and drywall. | |
09/05/2024 | COT - RSBU - Interior Shear Bracing | Passed |