Permit Reviews
Permit Number - TC-MDP-0223-00517
Permit Status: Complete
Permit Description: SFR MER2402850 T21-M0075
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
11/15/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 11/15/2024 | APPROVED |
07/29/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 07/31/2024 | APPROVED |
01/05/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 01/11/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0223-00517
Permit Status: Complete
Permit Description: SFR MER2402850 T21-M0075
Date | Description | Comments |
---|---|---|
01/05/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
01/05/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
01/05/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
01/09/2024 | Post-Tension Inspection Report is required. | |
01/05/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
01/05/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
07/31/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
01/09/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0223-00517
Permit Description: SFR MER2402850 T21-M0075
Total Completed Inspections - 22
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2024 | COT - RSPL - Backwater Valve | Passed | Underground plumbing & backwater valve are connected to main sewer line. Entire system is under a water test with no leaks. Okay to shade pipe and backfill trenches. | |
06/10/2024 | COT - RSPL - Rough Soil | Passed | Underground plumbing & backwater valve are connected to main sewer line. Entire system is under a water test with no leaks. Okay to shade pipe and backfill trenches. | |
06/10/2024 | COT - RSPL - Sewer | Passed | Underground plumbing & backwater valve are connected to main sewer line. Entire system is under a water test with no leaks. Okay to shade pipe and backfill trenches. | |
06/10/2024 | COT - RSPL - Yard Water Line | Passed | Main water supply line is installed from meter to house with blue tracer wire attached to pipe. System is under street pressure with no leaks. Okay to shade pipe and backfill trench. | |
06/18/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
06/18/2024 | COT - RSBU - Preslab | Passed | ||
06/18/2024 | COT - RSEL - Electrical Underground | Passed | ||
06/18/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
07/10/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 7/9/24: canceled per contractor 7/10/24: Plywood sheathing on exterior and interior shear walls is properly installed and secured to studs with nail pattern per the plan, exterior walls and interior walls are secured to the concrete floor with masa clips, shot pins, j-bolts, or titan bolts. Okay to proceed with rough-in of plumbing, mechanical, and electrical. |
|
07/10/2024 | COT - RSBU - Roof Nailing | Passed | 7/10/24: Roof trusses are properly secured to top plate with nails and H2.5 clips. Plywood sheathing is properly secured to trusses. Okay to proceed with mechanical, electrical, and plumbing rough-in. | |
08/09/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
08/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 8/12/24: DWV under test, pex water lines under pressure, rips and penetration in vapor barrier have been sealed, all registers are blocked out. Rough-in of mechanical, electrical, and plumbing is complete. Okay to proceed with installation of insulation and drywall. | |
08/15/2024 | BULD - Electrical Clearance | Passed | TEP ECO | |
09/03/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
10/09/2024 | COT - BULD - SWG Clearance | Passed | 10-9-24, approved for Southwest gas. | |
10/30/2024 | COT - RSEL - Electrical Final | Passed | Construction is complete to plan requirements. Okay to issue Certificate of Occupancy. | |
10/30/2024 | COT - RSEL - Outdoor Lighting | Passed | Construction is complete to plan requirements. Okay to issue Certificate of Occupancy. | |
10/30/2024 | COT - RSME - Mechanical Final | Passed | Construction is complete to plan requirements. Okay to issue Certificate of Occupancy. | |
10/30/2024 | COT - RSPL - Plumbing Final | Passed | Construction is complete to plan requirements. Okay to issue Certificate of Occupancy. | |
10/30/2024 | ENGR Engineering Final | Passed | ||
10/30/2024 | RSBU - Building Final | Passed | Construction is complete to plan requirements. Okay to issue Certificate of Occupancy. | |
10/30/2024 | RSBU - Building Progress | Passed | Construction is complete to plan requirements. Okay to issue Certificate of Occupancy. |