Permit: TC-MDP-0126-00017
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
9775 E PANOPEIA DR
Address NEW:
9775 E PANOPEIA DR
Apply Date:
02/12/2026
Applicant:
Celina Rodriguez
Description:
Mirador Ridge Blossom 2685 Plan (Model master plan TC-MDP-0725-00414)
Permit Reviews
Permit Number - TC-MDP-0126-00017
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 2685 Plan (Model master plan TC-MDP-0725-00414)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/18/2026 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 02/27/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0126-00017
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 2685 Plan (Model master plan TC-MDP-0725-00414)
Total Outstanding Activity Conditions - 5
| Date | Name |
|---|---|
| 01/14/2026 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 01/14/2026 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 02/19/2026 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 02/19/2026 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 02/19/2026 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0126-00017
Permit Status: Inspections
Permit Description: Mirador Ridge Blossom 2685 Plan (Model master plan TC-MDP-0725-00414)
| Date | Description | Comments |
|---|---|---|
| 01/14/2026 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 01/14/2026 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ | |
| 01/14/2026 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0126-00017
Permite Description: Mirador Ridge Blossom 2685 Plan (Model master plan TC-MDP-0725-00414)
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2026 | COT - RSPL - Sewer | N/A | Not Ready | 03/10/2026 Not ready. |
| 04/24/2026 | BULD - Electrical Clearance | N/A | Re-inspection required | 04/24/2026 Wrong address number at metal tag, missing underground riser conduit to meter base, label breakers. |
| 04/24/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 04/24/2026 Brace Pex line in downstairs bathroom as marked. Tape torn duct above kitchen, visible from stairs midway. Add Boca nail plates to top & bottom plates at gas line in primary bedroom upstairs and at vent tile in upstairs laundry room. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0126-00017
Permit Description: Mirador Ridge Blossom 2685 Plan (Model master plan TC-MDP-0725-00414)
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2026 | COT - RSPL - Rough Soil | Passed | 03/10/2026 Approved per plan, ok to backfill with shading. |
|
| 03/10/2026 | COT - RSPL - Yard Water Line | Passed | 03/10/2026 Approved per plan, ok to backfill with shading. |
|
| 03/19/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 3/19/2026 Corrections made. Okay to pour. |
|
| 03/19/2026 | COT - RSBU - Preslab | Passed | 3/19/2026 Corrections made. Okay to pour. |
|
| 03/19/2026 | COT - RSEL - Electrical Underground | Passed | 3/19/2026 Corrections made. |
|
| 04/02/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 04/06/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 04/06/2026 Corrections made to 4/2/26 inspection. |
|
| 04/24/2026 | COT - RSPL - Gas Pressure Test | Passed |