Permit: TC-MDP-0126-00017

Parcel: 141155610


Addresses:

9775 E PANOPEIA DR

Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
07/14/2026 COT - RSPL - Plumbing Final  Re-inspection required 07/14/2026
Finish circuit label schedule at dead front and indicate non-metallic plumbing, paint exposed plastic pipes, GFCI receptacle left of range does not reset, circuit in loft not working and adjacent bedroom. No ladder provided to verify attic equipment.
07/15/2026 COT - RSPL - Plumbing Final  Re-inspection required (with fee) 7/15/26: Per previous notes (kitchen GFCI not properly functioning left of range), panel Schedule incomplete and AFCI beaker that isn't labeled is tripping, lights at staircase not working, B-vent must be properly with proper clearance from combustibles (truss and roof sheathing), properly support bracket at b-vent, leak at hose-bib, properly install clean-out cap near panel, clean out cap must be properly installed at drive way. Reinspection fee required
07/21/2026 COT - RSPL - Plumbing Final  Passed All corrections were made. 7/21/2026