Permit: TC-COM-1224-02366
Permit Details
Status:
Inspections
Type:
Commercial Building
Address:
4945 S LIBERTY AV
Address NEW:
4945 S LIBERTY AV
Apply Date:
12/18/2024
Applicant:
Caleb Markosian
Description:
The scope of work involves the renovation of an existing 96 unit senior community apartment complex.
Permit Reviews
Permit Number - TC-COM-1224-02366
Permit Status: Inspections
Permit Description: The scope of work involves the renovation of an existing 96 unit senior community apartment complex.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/23/2024 | COMMERCIAL REVIEW - FULL v.1 | 01/15/2025 | REQUIRES RESUBMIT |
| 05/29/2025 | COMMERCIAL REVIEW - FULL v.2 | 06/04/2025 | REQUIRES RESUBMIT |
| 06/24/2025 | RESTAMP - COMMERCIAL v.1 | 06/25/2025 | APPROVED |
| 06/11/2025 | COMMERCIAL REVIEW - FULL v.3 | 06/11/2025 | REQUIRES RESUBMIT |
| 10/01/2025 | COMMERCIAL REVIEW - FULL REVISION v.2 | 10/07/2025 | APPROVED |
| 06/12/2025 | COMMERCIAL REVIEW - FULL v.4 | 06/24/2025 | APPROVED |
| 10/01/2025 | COMMERCIAL REVIEW - FULL REVISION v.1 | 10/01/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-1224-02366
Permit Status: Inspections
Permit Description: The scope of work involves the renovation of an existing 96 unit senior community apartment complex.
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 06/24/2025 | AIR BALANCING REPORT IS REQUIRED. |
| 06/24/2025 | WATER STERILIZATION REPORT IS REQUIRED. |
Conditions
Permit Number - TC-COM-1224-02366
Permit Status: Inspections
Permit Description: The scope of work involves the renovation of an existing 96 unit senior community apartment complex.
| Date | Description | Comments |
|---|---|---|
| 12/23/2024 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 12/23/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-COM-1224-02366
Permite Description: The scope of work involves the renovation of an existing 96 unit senior community apartment complex.
Total Outstanding Inspections - 11
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/20/2026 | COT - HCBU - Building Final | N/A | Re-inspection required | 2-20-26: called point of contact at 830am -no answer and unable to leave voice mail because it was full. Made contact with management at the office who said contractor was not on site and would be arriving sometime later. Please reschedule inspection at your convenience. |
| 03/06/2026 | COT - HCBU - Interior Shear Bracing | N/A | Partial Pass | 3-6-26: B101, B102-okay to continue with construction. C105-rough MEP's-fire foam all penetrations, add Boca plate to DWV in restroom and add strap. Okay for 5/8" drywall at firewall. |
| 03/19/2026 | COT - HCME - Mechanical Progress | N/A | Not Ready | Fire caulk all penetrations above ceiling throughout firewalls. 3/19/2026 |
| 03/19/2026 | COT - HCPL - Plumbing Progress | N/A | Not Ready | Fire caulk all penetrations above ceiling throughout firewalls. 3/19/2026 |
| 03/19/2026 | COT - HCEL - Electrical Progress | N/A | Not Ready | 3/19/2026 not ready. Room #c119. Extend electrical boxes so that when it's time for drywall they'll be flushed. Fire caulk all penetrations above ceiling into firewalls. No bundling more than 4 wires per hole. Smoke detectors not set in place along with kitchen receptacles. Secure loos wires vertically. |
| 02/27/2026 | COT - HCME - Mechanical Intermediate | N/A | Re-inspection required | 2-27-26: precon meeting & a general walk through of MEP's at Unit B101. Fire foam all penetrations at top plates, add supports to in wall DWV under test/Domestic lines at shower, install shower backing as required per City of Tucson Inclusive requirements, add plumbers tape to DWV above ceiling that is resting on 2x4, and have engineer or architect of record submit a letter showing slight relocation of electrical panel to adjacent wall at living room and note that existing panel will be utilized as a junction box. |
| 03/24/2026 | COT - HCPL - Plumbing Final | N/A | Partial Pass | 3-24-26: B102-Pending installation of ADA shower seats & shower liner/p-trap test. |
| 02/27/2026 | COT - HCPL - Plumbing Intermediate | N/A | Re-inspection required | 2-27-26: precon meeting & a general walk through of MEP's at Unit B101. Fire foam all penetrations at top plates, add supports to in wall DWV under test/Domestic lines at shower, install shower backing as required per City of Tucson Inclusive requirements, add plumbers tape to DWV above ceiling that is resting on 2x4, and have engineer or architect of record submit a letter showing slight relocation of electrical panel to adjacent wall at living room and note that existing panel will be utilized as a junction box. |
| 03/24/2026 | COT - HCME - Mechanical Final | N/A | Partial Pass | 3-24-26: mechanical final approved. |
| 03/24/2026 | COT - HCEL - Electrical Final | N/A | Partial Pass | 3-24-26: B102 approved. |
| 02/27/2026 | COT - HCEL - Electrical Intermediate | N/A | Re-inspection required | 2-27-26: precon meeting & a general walk through of MEP's at Unit B101. Fire foam all penetrations at top plates, add supports to in wall DWV under test/Domestic lines at shower, install shower backing as required per City of Tucson Inclusive requirements, add plumbers tape to DWV above ceiling that is resting on 2x4, and have engineer or architect of record submit a letter showing slight relocation of electrical panel to adjacent wall at living room and note that existing panel will be utilized as a junction box. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-COM-1224-02366
Permit Description: The scope of work involves the renovation of an existing 96 unit senior community apartment complex.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/05/2026 | PDSD Building Division Pre-Construction Meeting | Passed | ||
| 03/11/2026 | COT - HCBU - Building Progress | Passed | 3-11-26: 5/8" drywall screw inspection for unit C105 approved-okay to tape & texture progress areas. | |
| 03/17/2026 | TRSP - ROW - Final/Close-Out | Passed |