Permit: TC-COM-1125-02155
Permit Details
Status:
Complete
Type:
Commercial Building
Address:
7760 E SPEEDWAY BL
Address NEW:
7760 E SPEEDWAY BL
Apply Date:
11/26/2025
Applicant:
Deborah Sylva
Description:
NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Permit Reviews
Permit Number - TC-COM-1125-02155
Permit Status: Complete
Permit Description: NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW
NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/06/2026 | COMMERCIAL REVIEW - FULL v.2 | 01/20/2026 | APPROVED |
| 03/02/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 03/05/2026 | APPROVED |
| 01/21/2026 | ADMINISTRATIVE v.1 | 01/21/2026 | REQUIRES RESUBMIT |
| 01/23/2026 | ADMINISTRATIVE v.2 | 01/23/2026 | APPROVED |
| 01/20/2026 | RESTAMP - COMMERCIAL v.1 | 01/21/2026 | APPROVED |
| 12/04/2025 | COMMERCIAL REVIEW - FULL v.1 | 12/30/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-COM-1125-02155
Permit Status: Complete
Permit Description: NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW
NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
| Date | Description | Comments |
|---|---|---|
| 03/04/2026 | AIR BALANCING REPORT IS REQUIRED. | |
| 12/04/2025 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 12/04/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 03/04/2026 | WATER STERILIZATION REPORT IS REQUIRED. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-COM-1125-02155
Permite Description: NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW
NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/26/2026 | COT - HCPL - Sewer | N/A | Not Applicable | |
| 02/27/2026 | COT - HCPL - Plumbing Roof Drains | N/A | Not Applicable | |
| 03/06/2026 | BULD - Electrical Clearance | N/A | Not Applicable | power already on |
| 03/06/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 03/06/2026 | ENGR Engineering Final | N/A | Not Ready | 6/3/25 Dumpster, Connex box, Portajohn, equipment and materials on site. Reschedule inspection when these items are removed and access is clear. |
| 03/09/2026 | COT - HCPL - Plumbing Final | N/A | Canceled |
Completed Inspections
Permit Status: Complete
Permit Number: TC-COM-1125-02155
Permit Description: NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW
NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Total Completed Inspections - 25