Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Complete
Type:
Commercial Building
Address NEW:
7760 E SPEEDWAY BL
Apply Date:
11/26/2025
Applicant:
Deborah Sylva
Description:
NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.

Permit Reviews

Permit Number - TC-COM-1125-02155
Permit Status: Complete
Permit Description: NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Start Date Submittal Complete Date Status  
01/06/2026 COMMERCIAL REVIEW - FULL v.2 01/20/2026 APPROVED Review Details
03/02/2026 BUILDING DEFERRED SUBMITTAL REVIEW v.1 03/05/2026 APPROVED Review Details
01/21/2026 ADMINISTRATIVE v.1 01/21/2026 REQUIRES RESUBMIT Review Details
01/23/2026 ADMINISTRATIVE v.2 01/23/2026 APPROVED Review Details
01/20/2026 RESTAMP - COMMERCIAL v.1 01/21/2026 APPROVED Review Details
12/04/2025 COMMERCIAL REVIEW - FULL v.1 12/30/2025 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-COM-1125-02155
Permit Status: Complete
Permit Description: NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Date Description Comments
03/04/2026 AIR BALANCING REPORT IS REQUIRED.
12/04/2025 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
12/04/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
03/04/2026 WATER STERILIZATION REPORT IS REQUIRED.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-COM-1125-02155
Permite Description: NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
01/26/2026 COT - HCPL - Sewer N/A Not Applicable
02/27/2026 COT - HCPL - Plumbing Roof Drains N/A Not Applicable
03/06/2026 BULD - Electrical Clearance N/A Not Applicable power already on
03/06/2026 COT - BULD - SWG Clearance N/A Not Applicable
03/06/2026 ENGR Engineering Final N/A Not Ready 6/3/25
Dumpster, Connex box, Portajohn, equipment and materials on site. Reschedule inspection when these items are removed and access is clear.
03/09/2026 COT - HCPL - Plumbing Final N/A Canceled

Completed Inspections

Permit Status: Complete
Permit Number: TC-COM-1125-02155
Permit Description: NTERIOR TENANT IMPROVEMENT OF AN EXISTING 2,372 SF TENANT SPACE. WORK INCLUDES NEW NON-BEARING PARTITIONS, DOORS, DROP CEILINGS, MILLWORK, NEW ELECTRICAL, PLUMBING AND MECHANICAL DISTRIBUTION.
Total Completed Inspections - 25
Date Description Inspector Results Comments
01/26/2026 COT - HCEL - Electrical Underground Passed
01/26/2026 COT - HCPL - Rough Soil Passed
02/05/2026 COT - HCBU - Framing Passed
02/05/2026 COT - HCBU - Interior Shear Bracing Passed
02/05/2026 COT - HCBU - Preslab Passed
02/05/2026 COT - HCME - Mechanical Intermediate Passed
02/05/2026 COT - HCPL - Plumbing Intermediate Passed
02/05/2026 COT - HCEL - Electrical Intermediate Passed
02/20/2026 COT - HCBU - Building Above Ceiling Passed
02/20/2026 COT - HCEL - Electrical Above Ceiling Passed
02/20/2026 COT - HCME - Mechanical Above Ceiling Passed
02/20/2026 COT - HCPL - Plumbing Above Ceiling Passed
02/20/2026 COT - HCPL - Plumbing Progress Passed
02/20/2026 COT - HCME - Mechanical Progress Passed
02/20/2026 COT - HCEL - Electrical Progress Passed
02/27/2026 COT - HCME - Venting Passed
03/06/2026 COT - FCON - Fire - Final Passed
03/06/2026 TRSP - ROW - Final/Close-Out Passed
03/06/2026 COT - HCBU - Exterior Clips/Sheathing Passed Passed 3/6/26
03/09/2026 ENGR Engineering Final Passed Portajohn left in parking lot is scheduled for pick up today. Otherwise, all clear.
03/10/2026 COT - HCPL - Plumbing Final Passed
03/10/2026 COT - HCBU - Building Final Passed
03/10/2026 COT - HCBU - CofO Passed
03/10/2026 COT - HCEL - Electrical Final Passed
03/10/2026 COT - HCME - Mechanical Final Passed