Permit: TC-COM-1123-02681
Permit Details
Apply Date:
11/16/2023
Applicant:
JASON GRECO
Description:
Proposed 9,109 square foot Early Childcare Facility with a 7,168 square foot outdoor playground.
Permit Reviews
Permit Number - TC-COM-1123-02681
Permit Status: Issued
Permit Description: Proposed 9,109 square foot Early Childcare Facility with a 7,168 square foot outdoor playground.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
12/21/2023 | COMMERCIAL REVIEW - FULL v.2 | 01/16/2024 | REQUIRES RESUBMIT |
02/13/2024 | RESTAMP - COMMERCIAL v.1 | 02/26/2024 | APPROVED |
01/19/2024 | COMMERCIAL REVIEW - FULL v.3 | 02/13/2024 | APPROVED |
11/20/2023 | COMMERCIAL REVIEW - FULL v.1 | 12/15/2023 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-COM-1123-02681
Permit Status: Issued
Permit Description: Proposed 9,109 square foot Early Childcare Facility with a 7,168 square foot outdoor playground.
Total Outstanding Activity Conditions - 6
Date | Name |
---|---|
12/28/2023 | SPECIAL INSPECTION FOR BOLTS INSTALLED IN CONCRETE IS REQUIRED. |
12/28/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
12/28/2023 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
12/28/2023 | SPECIAL INSPECTION FOR OUTDOOR LIGHTING IS REQUIRED. |
12/28/2023 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
12/28/2023 | SPECIAL INSPECTION FOR STRUCTURAL MASONRY IS REQUIRED. |
Conditions
Permit Number - TC-COM-1123-02681
Permit Status: Issued
Permit Description: Proposed 9,109 square foot Early Childcare Facility with a 7,168 square foot outdoor playground.
Date | Description | Comments |
---|---|---|
11/20/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
11/21/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. |
Outstanding Inspections
Permit Status: Issued
Permit Number: TC-COM-1123-02681
Permite Description: Proposed 9,109 square foot Early Childcare Facility with a 7,168 square foot outdoor playground.
Total Outstanding Inspections - 7
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/20/2024 | COT - HCEL - Grounding/Bonding | N/A | Partial Pass | 6/20/24: partial for UFER ground. |
07/23/2024 | COT - HCBU - Excavation/Rebar/Zoning | N/A | Partial Pass | 7/23/24: partial for entry and patio stem walls |
07/19/2024 | COT - HCPL - Plumbing Intermediate | N/A | Partial Pass | 7/19/24: partial to back fill underground plumbing, will need inspection for grease trap in pantry |
07/26/2024 | COT - HCEL - Electrical Intermediate | N/A | Partial Pass | 7/26/24: PARTIAL PASS: 2--4" Electrical conduit through stem wall for secondary service, 2--3" conduits each for 600 amp and 400 amp service panels are installed from main electrical room location to interior electrical room, 2--3" conduits are installed from main electrical room to interior electrical room, and 1--1" conduit is installed from interior electrical room to 5' outside of east wall footing for site lighting. Okay to backfill and compact electrical trenches. |
09/18/2024 | COT - HCBU - Framing | N/A | Partial Pass | 9/18/24: partial for nailing at exterior shear walls |
09/18/2024 | COT - HCBU - Roof Nailing | N/A | Partial Pass | 9/18/24: partial for nailing at main roof |
BULD - Electrical Clearance | N/A | Requested |
Completed Inspections
Permit Status: Issued
Permit Number: TC-COM-1123-02681
Permit Description: Proposed 9,109 square foot Early Childcare Facility with a 7,168 square foot outdoor playground.
Total Completed Inspections - 1
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/08/2024 | COT - HCBU - Preslab | Passed |